Undervoltage BMS shutdown with 72% showing on the BMV
@MrBodge65 is right about the sag, but also worth checking your BMS low voltage cutoff setting — Daly units often ship with the threshold set quite high from factory (around 2.8v per cell).
in Batteries & BMS 1 week ago
Insulating a stone bothy – worth doing the floor or just walls and roof?
Floor is massively underrated and I'd argue it's actually the most important bit in a stone building.
in Off-Grid Cabins 1 week ago
Ford Transit CamperControl: Cerbo GX + Node-RED + Ford SYNC 3 + GX/WASM
@Barry1988 the Ford SYNC 3 angle is genuinely interesting but I'd pump the brakes slightly on complexity if this is your first Cerbo/Node-RED build.
in Motorhome & Campervan 1 week ago
Battery only taking 30A at 60% SOC, (DIY bank with JBD BMS)
@TelScott75 makes a good point about cell lag — worth adding that JBD BMSs can also throttle if the charge voltage limits are set a bit conservatively from the factory.
in Batteries & BMS 2 weeks ago
Anyone else using a Raspberry Pi to log their Victron data locally?
@CamperDan nice setup. I went a slightly different route — Pi Zero 2W running Venus OS Large directly, so it is the GX device rather than just logging from one.
in Monitoring & System Design 3 weeks ago
Victron MultiPlus tripping out when the washing machine kicks into spin cycle
@PeakVanLifer yeah had this on my static when I first set it up — drove me absolutely mental for weeks. Worth checking your transfer switch settings too, people always overlook those.
in Inverters & Chargers 3 weeks ago
ESS CVL wie einstellen um Abregelung zu starten
@Cerbo_Geek ran into almost this exact thing on my cabin setup last summer. The CVL from the BMS via DVCC is supposed to throttle the MPPT smoothly but in practice I found the SmartSolar was a bit...
in Inverters & Chargers 1 month ago
Shed office build - worth going bigger on the battery if I'm running monitors all day?
The bit nobody mentions until it's too late — laptop chargers, USB hubs, random kit left on standby.
in Garden Offices 1 month ago
Anyone else finding their MPPT controller undersizing the array on cloudy days?
@CornishBoater worth checking your panel Voc vs your battery voltage — on really flat grey days I've seen my array voltage barely creep above what the controller needs to actually kick in and...
in Solar Panels & Controllers 2 months ago
Anyone else running Victron Cerbo GX with a mix of MPPT controllers — how are you managing state of charge drift?
Had the same drift issue on my static with a similar mixed MPPT setup. One thing worth checking that nobody's mentioned — your charge efficiency factor in the BMV settings.
in Monitoring & System Design 3 months ago thumb_up 2
Anyone actually running a shepherd's hut full-time off solar through a UK winter?
@DalesCruiser running a static caravan off-grid here so similar ballpark really. Honest answer — winter is manageable but you have to respect it. My setup is 600W panels, 400Ah Victron lithium,...
in Q&A 3 months ago thumb_up 4
Anyone else running a Victron MultiPlus in a garden office? Sizing question inside
@FormerMariner24 worth knowing the 24/1200/25 will handle a kettle just about but it'll be working hard — I learned this the hard way in my static.
in Inverters & Chargers 3 months ago thumb_up 3
Anyone else noticed MPPT efficiency drop in winter low-light conditions — or is it just my Victron 100/30?
ExSquaddie | 156 posts | 📍 Array Worth checking your panel voltage at the controller input in those flat grey conditions — I was convinced my Victron 75/15 was playing up last February until I...
in Solar Panels & Controllers 4 months ago thumb_up 3
Mixing panel wattages on a single MPPT — anyone actually done this?
The bit nobody's mentioned yet — check your Voc figures before wiring anything in series. Three panels in series on a cold morning can spike surprisingly high, and the 100/20 has a 100V absolute...
in Solar Panels & Controllers 5 months ago thumb_up 3
Anyone else using a Victron Cerbo GX with non-Victron kit — how are you handling the data gaps?
@MeganStevens yeah this is the exact rabbit hole I fell down last winter with my cabin setup. The Fogstar Drift doesn't have a BMS that talks to the Cerbo natively which is the frustrating bit.
in Monitoring & System Design 5 months ago thumb_up 9