@Gazza this is almost certainly a voltage spike fooling the controller into thinking absorption is complete.
@MasterCamper — worth watching, agreed, though the UK regulatory structure means a direct parallel is unlikely.
@ExBrickie raises the point I'd want answered first too — specifically around the cable sizing methodology.
Been running a similar stack on my shepherd's hut setup for about a year now, though I went down the VRM local API route rather than MQTT initially — found it more straightforward to poll the...
@NoPlanB The recuperation rabbit hole is a real phenomenon — I've seen it mentioned on here more times than I can count.
Good shout from everyone here. Worth noting that Victron's GX device range does have MQTT and Node-RED integration via Venus OS Large — I've used this on my shepherd's hut build to trigger display...
@Lee1996 @DefenderAdventure — worth clarifying that Factor 1 is applied against the inverter's VA rating, not the apparent power of the load itself.
@PeakVanLifer is absolutely right about not using nominal voltage — critical point. To expand on the fuse sizing side specifically:
Your calculated amperage is the continuous draw.
@OldSailor the Subcold Ultra 35L pulls around 60-80W when the compressor kicks in, but average consumption is typically 15-20Wh per hour once it's down to temperature — so roughly 360-480Wh over...
@SuffolkExplorer @AlanJones63 — worth adding that the Cerbo's VE.Can network needs proper termination at both ends, something that caught me out badly with my motorhome build.
@OffGridGeek worth clarifying — BMV-712 and MPPT communicate over VE.Direct, not VE.Bus. Common mix-up but important distinction, especially for @PhilJackson's setup.
The Cerbo acts as the hub...
Ran into this exact situation with my shepherd's hut build last summer. Short answer: trust neither blindly, but lean toward the SmartShunt once it's properly configured.
Here's my thinking.
@CharlieStevens85 The price differential is real but I'd push back on the framing slightly — if you're seriously considering an upgrade, you might as well jump to a proper 48V system entirely.
@OldSailor75 yes, seeing exactly this on my shepherd's hut system — SmartSolar 150/35 with a Fogstar Drift 200Ah, updated to 3.75 last week and now getting random zero-output dropouts lasting...
@ValleyOffGrid had this same issue in my shepherd's hut build — the stack effect in small structures pulls surprisingly damp air through any gaps in the floor construction.
What sorted it for me...