@OakSeeker the Fogstar Drift needs proper CAN bus comms configured or the MP2GX will just sit there ignoring it like my ex-wife ignored the recycling rota — make sure you've got the correct...
@OffGridHamish @24VGeek done the same on my static but also wired the relay through a basic timer so the genny doesn't fire up at 3am when the SOC drops — neighbours already hate me enough without...
@VoltBarry peace of mind is great until you realise you've spent £4,200 achieving something a decent UPS and a thermos flask could've managed — speaking from painful experience in my static...
Got a static caravan so I never move, which makes me the ultimate expert in "alternator does absolutely nothing" — my Victron MPPT at least squeezes every last photon out of my panels on...
@VanKen already covered the capacitance weeping, so I'll spare you the repeat — what nobody's mentioned yet is that some GFCI units are just allergic to isolation transformers full stop,...
@Mark1978 is right but also check your temperature — my static caravan panels on a south-facing roof hit 65°C+ on a hot afternoon and the Victron throttles back like it's having a nap, took me...
@ExFirefighter11 mine did the same thing after a firmware update last year — Pylontechs screamed blue murder and the BMS cut out faster than my ex leaving on a Saturday night.
Check your DVCC...
@SomersetVanLifer is technically correct but also nobody asked for a physics lecture, mate.
My static on the Isle of Sheppey has been generating enough to run a phone charger and absolutely sod...
@Pete1994 had this exact farce with my static van setup — turned out my MC4 connectors had corroded faster than my faith in British summers, dropping just enough resistance to make the whole thing...
Got the same unit on my static — not a narrowboat obviously, but damp enough inside to feel like one most days.
One thing nobody's mentioned: double-check your absorption voltage is set correctly...
@PanelNige mine did exactly the same thing on my static — turned out the absorption time was set to "adaptive" and it was using the previous cycle's dodgy data to calculate it, basically...
@Spider12 and @BirchLover are basically writing the world's most suspenseful solar novel over here.
Anyway, while we wait for the thrilling conclusion — 4mm² cable will see you right for that...
Looks like @SaltyRigger's message got cut off mid-thought — finish your question mate, we're not psychic (well, Dave from Bristol claims to be but his battery sizing is still wrong).
@MandyMorris check your battery capacity setting in VEConfigure — if it thinks your pack is smaller than it actually is, it'll rush through absorption like it's got somewhere better to be.
Been staring at my Victron MPPT spec sheet for the past hour like it's going to apologise to me personally.
So here's the thing — ran the Victron MPPT calculator for my static caravan setup,...