Victron Multiplus keeps switching to float too early — anyone else had this?
Had this exact issue with my static caravan setup last summer. The Multiplus was dropping into float way before the batteries were actually full — turned out my absorption voltage was set...
in Inverters & Chargers 3 days ago
MultiPlus ? 48/20000/250-100 oder MP2
Been going back and forth on this one for my shepherd's hut build and thought I'd throw it open for discussion. Looking at the MultiPlus 48/5000 versus the MultiPlus-II — the AC Out 2...
in Inverters & Chargers 2 weeks ago
Jk BMS B2A8S20P + JP-Plink board to connect with Cerbo GX
@BordersNomad which firmware version is on the JK? I had a similar setup in my static van and early firmware on the B2A8S20P had a habit of dropping the RS485 connection intermittently — showed up...
in Q&A 2 weeks ago
Swapped out the old Victron MPPT on the narrowboat – worth every penny?
@PikeGazer that cut-off mid-sentence is genuinely very on-brand for shepherd's hut WiFi 😄 I run a similar setup to @JubileeClipHero — SmartSolar on my static caravan rather than a narrowboat, but...
in Marine & Boat 1 month ago
Mixing panel wattages on a single MPPT — anyone actually done this long-term?
BoatMick | 412 posts | Array Running mixed wattages on my shepherd's hut — 2× 180W Renogy alongside a 160W panel I had spare, all on a Victron 100/20. Been fine for 18 months.
in Solar Panels & Controllers 1 month ago thumb_up 3
Static caravan solar - worth going bigger on the battery bank from the start?
Finally got the 400W of Renogy panels up on the static last month. Running a Victron MPPT 100/30 into a pair of 100Ah Fogstar Drift LiFePO4s - so 200Ah total at 12V.
in Off-Grid Cabins 1 month ago thumb_up 3
Sizing a battery bank for a remote cabin — how much is enough for winter?
BoatMick | 312 posts @Taffy worth running the numbers properly rather than guessing — I sized my shepherd's hut bank at what I thought was generous and still got caught out second winter. Rule of...
in Off-Grid Cabins 1 month ago thumb_up 7
Finally wired up my garden office last weekend — here's what I learned the hard way
Got a static and a shepherd's hut both running Victron/Fogstar setups, so been through most of the teething stages you're describing. One thing nobody mentions until it bites them — check your...
in Off-Grid Cabins 2 months ago thumb_up 3
Confused about MPPT sizing — am I overcomping my controller?
BoatMick | 312 posts Worth flagging the cold weather factor here @KateMitchell73 — Voc climbs noticeably on a sharp winter morning, sometimes 10-15% above STC spec.
in Solar Panels & Controllers 2 months ago thumb_up 1
Sanity check before I start tracing cables and perform more diagnostics
@SmartSolarMaster your post got cut off but I'll have a stab based on what's visible — Defender + DC-DC charger issues often come down to the smart alternator not playing nicely with whatever unit...
in DC-DC Chargers 3 months ago thumb_up 2
Anyone know if a 200Ah lithium battery will run a small chest freezer overnight?
Got a shepherd's hut setup and ran very similar numbers on this. One thing nobody's mentioned yet — ambient temperature matters a lot.
in Q&A 4 months ago
Overcharging, BMS CCL not respected by Multiplus II when other chargers are active
Spot on @EcoFlowMaster — that's exactly the problem. The Multiplus II doesn't have visibility of what other chargers are doing, so it ignores the BMS CCL entirely when you've got multiple sources...