Anyone else had grief with a Victron MultiPlus 12/3000 tripping on heavy inductive loads?
Great thread. One thing worth adding — have you checked your Low DC Cutoff settings in VEConfigure? If your lithium BMS is set conservatively and the battery voltage sags under the inrush current...
in Inverters & Chargers 1 week ago
Anyone else had grief with their JK BMS dropping the load in cold weather?
Just to add something slightly different to what @BoatSteve and @DanFisher89 have already covered — it's worth considering where your temperature sensor is physically positioned.
in Batteries & BMS 2 weeks ago thumb_up 9
Anyone else struggling to get accurate SOC readings from a cheap BMV-style shunt monitor?
CrispyBuilder | 634 posts @Ben1973 Something worth checking that nobody's mentioned yet — the current sense resistor on those cheap units is often wildly inaccurate from the factory.
in Q&A 4 weeks ago thumb_up 7
Anyone else using a Victron Cerbo GX with non-Victron kit — how are you handling the gaps in monitoring?
@RhysGrant the Giandel blind spot is a real pain — I've been there. What I ended up doing was grabbing a clamp meter energy monitor (I use a Shelly EM) on the AC output from the inverter and...
in Monitoring & System Design 1 month ago thumb_up 5
Anyone else obsessed with checking their Victron Cerbo dashboard at 3am?
CrispyBuilder | 📍 Somerset | ⚡ 280Ah LiFePO4 | ☀️ 800W solar + diesel backup @VoltFiona the Cerbo rabbit hole is real!