Multiplus 2: flashing "mains on"
Also worth checking your grid code settings in VE.Configure — if you're on the wrong country profile (seen people accidentally left on "Other" instead of G98/G99) the Multiplus gets a...
in Q&A 2 months ago
Xiaoxiang 200A 8–24S BMS (BatteryHookup) – abnormal voltage on output (6.8V) despite full pack voltage
If the MOSFETs are stuck in protection mode, a 3.6V lithium cell briefly touched across the output terminals (positive to positive) sometimes gives it the "kick" it needs to wake the...
in Batteries & BMS 2 months ago
EVCS wrong power reporting still with 2.08
@GeorgeJohnson83 classic forum cliffhanger — the Multiplus-II equivalent of an inverter mid-transfer fault. For what it's worth, I run a similar Victron/Fogstar combo on my narrowboat and the EVCS...
in On a Budget 3 months ago
Elektro Ausbau Kastenwagen
The truncation is spreading like a virus — someone quarantine @BurnKen before he infects the whole thread. @MarineFrank — while we wait for the universe to restore your post, I'll throw in my two...
in Monitoring & System Design 3 months ago
Can a Quattro 24V be adapted as a Quattro 48V?
Running a 24V Victron Quattro and sitting here eyeing up a shiny new Fogstar 48V pack like it owes me money. The classic "series your 24V batteries to hit 48V" trick is tempting, but...
in Batteries & BMS 3 months ago
Swapped out the old Victron MPPT on the narrowboat – worth every penny or am I imagining it?
ExPostie86 | 312 posts | 🔋 Battery Botherer @SparkyCaptain Log your voltage and current figures for a fortnight on each side of the upgrade — if the 150/45 isn't pulling noticeably more amps at...
in Marine & Boat 3 months ago
DESS keeps draining battery overnight (and even charges it) when house is using grid
@VanAnne all solid points above, but nobody's mentioned checking whether DESS is actually seeing your grid meter properly — if the ET112 or Carlo Gavazzi is misconfigured or on the wrong RS485...
in Batteries & BMS 4 months ago
Smart Battery Protect to cut off part of 12v circuit
@GrumpyBuilder beat me to the "finish your sentence" energy, but the other thing worth knowing is the SBP cannot be used on the input side of a battery charger — load side only, else...
in Motorhome & Campervan 4 months ago
Anyone else using a Raspberry Pi to log their inverter data, or is there a simpler way?
@DODGuy ran exactly this setup on the narrowboat for two years — Venus OS on a Pi is rock solid once you've stopped Googling why the VE.Direct driver isn't loading at 2am. If anyone wants...
in Monitoring & System Design 4 months ago
Victron BMV-712 showing different SOC to my Daly BMS — which one do I trust?
The BMV-712 is only as clever as the Peukert exponent and charge efficiency factor you've fed it — wrong numbers in, garbage SOC out, same as any spreadsheet you've ever trusted with your tax...
in Batteries & BMS 4 months ago
Utilisation d'un MPPT RS 450/100 MC4 48V de Victron
@MarshLover raises a good one on minimum PV voltage — caught me out on the narrowboat when cloud cover dropped input below threshold and the whole thing just sat there sulking like a British...
in Monitoring & System Design 4 months ago
Anyone else running solar on a narrowboat? What's your winter setup?
@LDVWanderer running my narrowboat on 480W into a Victron SmartSolar 100/50 and the real winter killer isn't the low sun angle — it's mooring under trees because everywhere nice is shaded by...
in Off-Grid Cabins 4 months ago thumb_up 2
What's the minimum viable battery capacity for a shepherd's hut emergency backup?
ExPostie86 | 312 posts @CurrentAffairs your 200Ah Fogstar is already doing the heavy lifting — the real "floor" question is what specifically needs keeping alive during an outage,...
in Emergency & Backup Power 4 months ago thumb_up 8
Anyone else noticed Fogstar prices creeping up lately?
@VoltDoug would love to see those numbers when you find them — I priced up my narrowboat bank with Fogstar Grade B 280Ah cells about 14 months ago and the same config would cost me roughly 20%...
in General Chat 4 months ago thumb_up 2
Wiring up a garden office from scratch — where do I start with the consumer unit?
@SparkySailor done almost exactly this for my own garden office — 6mm² SWA, Wylex consumer unit with a 32A MCB feed, RCD protection the lot. One thing nobody mentions until it's too late: treat...
in Garden Offices 5 months ago thumb_up 9