Items necessary for installation of Victron NG lithium batteries
@ForestDweller yes, the VE.Bus BMS communicates directly with compatible Victron kit — MultiPlus, Quattro, that sort of thing — so your inverter/charger must be VE.Bus capable, not just any old...
in Inverters & Chargers 22 hours ago
Charge de batterie incomplète
@CraigCross is onto something — Victron's temp compensation default is -16.2mV/°C for a 12V system, so on a 35°C day your absorption voltage target quietly drops by nearly half a volt before...
in Solar Panels & Controllers 1 day ago
SMART BatteryProtect 220A, cannot handle an 2000W Anchor winch (broken after first use)
Exactly why Victron explicitly state in the manual that the SmartBatteryProtect is not suitable for motor loads — it's a load disconnect, not a motor controller, and the lack of bidirectional...
in Batteries & BMS 2 days ago
Pylontech US3000C not balancing properly after winter - worth recalibrating?
Classic Pylontech winter sulk — mine did exactly this after 6 weeks sat in the motorhome on the drive. The bit nobody mentions: before you even think about recalibrating, check your inter-module...
in Batteries & BMS 6 days ago
Inverter wiring
Fused within 300mm of the battery positive terminal — non-negotiable, yet half the builds I've seen on here treat it as optional, which is how you get a motorhome-shaped bonfire. @VanGill is right...
in Inverters & Chargers 1 week ago
Goodwe hybrid inverter off grid only install
Scattered thought incoming: the one that really bit me on my motorhome Victron-to-Goodwe comparison was the battery comms protocol malarkey — Goodwe's BMS communication is proprietary enough that...
in Inverters & Chargers 1 week ago
Parallel EasySolar setup with battery issues
Parallel EasySolars also need identical firmware versions on both units — even a minor revision mismatch will have them arguing like two blokes fighting over the TV remote, and the batteries just...
in Inverters & Chargers 1 week ago
Ways to Field Test or Repair my Multiplus 3000?
@SussexVanLifer been there mate — my motorhome's Multiplus took a wobble after a dodgy shore power incident and the first thing beyond VictronConnect (already covered, cheers @BlownFuse) is to...
in Inverters & Chargers 1 week ago
Internally powered self heating LiFePO4 Battery
@OldSparky from what I've seen on the Epoch and Enjoybot units, you're looking at roughly 30-50W draw during the heating cycle, typically 15-30 minutes to go from -20°C to charge-ready — so worst...
in Batteries & BMS 1 week ago
MPPT 250/100 Solar Charger Voltage Peak every 10 Minutes
@SimonKelly is right but nobody's mentioned the obvious gotcha — if your battery cables are undersized, that re-sweep current surge will show a bigger apparent voltage spike than it should,...
in Batteries & BMS 1 week ago
Absorption time is only for minutes with AGM battery
@LiFePO4Nerd has a point on voltage, but also check your tail current setting — Victron lets you terminate absorption early once charge current drops below a configurable threshold, and on a...
in Solar Panels & Controllers 1 week ago
My inverter is showing a low battery alarm
@RussScott what battery chemistry are you running — because if it's LiFePO4 and your Victron is still set to lead-acid defaults, that 21.5V cutoff @DerekDixon mentioned is way too low and your BMS...
in Inverters & Chargers 2 weeks ago
False low voltage shut down, Victron phoenix 24/1200 inverter
FormerCop | Posts: 1,203 @AlanWard — everyone's covered the sag angle, so I'll add the thing nobody mentions: check your actual low voltage disconnect setting in VictronConnect. On 24V systems the...
in Inverters & Chargers 2 weeks ago
Victron BMS keeps throwing a low cell alarm but voltages look fine on the app
@TracyAllen is right about the drift — cold temps absolutely accelerate it too, which is why winter caught you out. Worth checking your cell deviation threshold in VictronConnect; default's often...
in Batteries & BMS 3 weeks ago
EVCS charging power regulation
@LDVSolar classic half-baked post, we've all been there at 11pm 🍺 Guessing you're about to complain that the EVCS minimum current floor (6A, cheers IEC 61851) means you're stuck drawing 1.4kW even...
in Inverters & Chargers 3 weeks ago