Victron Multiplus keeps dropping to float too early — anyone else had this?
@Chris1966 worth checking your absorption voltage setting too — if it's been drifted down slightly (common after firmware updates resetting parameters), the BMS on the Fogstar cells may be...
in Inverters & Chargers 4 days ago
ESS immediately shifts to 63 Hz and disconnects Huawei inverter when AC Input is present but rejecte
@48VWizard one thing worth double-checking that nobody's mentioned yet — your AC Input current limit within the ESS assistant itself.
in Batteries & BMS 2 weeks ago
Worth swapping AGM to lithium in a tiny house setup — numbers don't quite add up for me?
@LDVAdventure the usable capacity argument is where lithium really wins on paper, but your numbers need to account for the full charge cycle.
in Q&A 1 month ago thumb_up 9
Anyone else found that cheap Amazon PWM controllers absolutely murder your batteries in winter?
HeathOllie | 847 posts | ⭐⭐ Veteran The temperature compensation point has been covered well, but there's another angle worth raising: PWM controllers fundamentally cannot drive a partial charge...
in General Chat 2 months ago thumb_up 3
Mixing panel wattages on a single MPPT — anyone actually done this long-term?
HeathOllie | 📍 Array | ⚡ Posts: Garden Office Enthusiast The critical thing nobody's spelling out clearly: mixing wattages is fine, mixing Isc values is where you get into trouble on a series...
in Solar Panels & Controllers 2 months ago thumb_up 7
Anyone else had grief with a Victron Multiplus cutting out under load? (240V kettle test)
Both good points from @LB_Camper and @Robbo51, but I'd add one thing nobody's mentioned yet: check your low voltage disconnect threshold in VictronConnect. On a 12V Multiplus, the inverter will...
in Inverters & Chargers 2 months ago
Anyone else finding Fogstar Drift cells need a full balancing cycle before first use?
HeathOllie | 1,203 posts @RustySkipper worth noting that the voltage spread you're describing (roughly 40mV) is actually fairly modest for cells that have been sitting in a warehouse.
in Batteries & BMS 3 months ago thumb_up 9
Fitting a 200Ah lithium bank on a 28ft sailing cruiser — where did you route your cables?
Good thread. One thing I'd add from my garden office install (not marine, granted, but the cable sizing logic transfers) — don't underestimate voltage drop across long runs when you're pulling...
in Marine & Boat 3 months ago thumb_up 4
Migration from 48V Pylontech to Eco-worthy at 51.2V
@BayJason raises the CAN comms point which is important, but worth expanding on: without native BMS communication, your Victron kit won't receive dynamic charge current limits from the battery.
in Batteries & BMS 4 months ago
Ladealgorithmus mit externer Steuerung anzeigen?
Good points from @Ella1974 on the marine angle — corrosion on VE.Bus or VE.Direct connectors is a genuine gremlin that'll corrupt your charge state display without any obvious alarm. One thing...
in Batteries & BMS 4 months ago