@RussMartin one thing nobody's mentioned yet — check your cell capacity settings in the JK app. If the capacity figure is set too low, the BMS can calculate a false state of charge and trigger...
JulieEvans | 📍 Shropshire | ⚡ 24V LiFePO4 | Posts: 156
Had this exact headache last spring! What sorted it for me was bumping the Balance Start Voltage up to around 3.40V so it only kicks in...
@JulieEvans:
@LizWalker I know exactly what you mean about assumptions! We had a 7-hour outage back in February and my "sorted" setup revealed a few surprises.
@Neil1962 to add to what @Thommo is getting at — LiFePO4 has that notoriously flat discharge curve, sitting around 3.2-3.3V per cell across most of its usable capacity.
Hey @SophieClark, yes, absolutely seeing this! I'd wager your controller is relying too heavily on voltage-based SOC estimation rather than coulomb counting, and in winter the lower panel output...
I've been running a Victron MPPT 100/30 and a SmartShunt on my narrowboat for about eight months now, and whilst the VRM portal is handy enough, I really don't want to rely on a mobile data...
Really feel for @BoxerCamper and @DodgyMechanic dealing with marina shore power — it's a surprisingly common problem that doesn't get talked about enough.
We use essential cookies to keep you logged in and provide core website functionality. We do not use advertising or tracking cookies. See our Privacy Policy for details.
Cookie Details
Session cookies (strictly necessary): These cookies are essential for the website to function. They keep you logged in and maintain your session. They are automatically deleted when you close your browser. These cookies do not require consent under UK GDPR/PECR.
Local storage: We store your cookie consent preference and some UI preferences in your browser's local storage. This data never leaves your device.
Report an Issue
Thank you for reporting this issue. We'll review it as soon as possible.