Victron MPPT keeps dropping to float too early — anyone else had this?
Had this exact issue with my 100/30 last spring. Turned out the absorption voltage was set correctly but the absorption time was far too short — Victron's adaptive algorithm calculates it based on...
in Solar Panels & Controllers 18 hours ago
Victron BMV-712 showing different SOC to my Daly BMS — which one do I trust?
@PartnerCamper is right, but worth understanding why the discrepancy exists rather than just blindly trusting one over the other. The Daly calculates SOC primarily from cell voltage, which is...
in Batteries & BMS 1 month ago
ESS JK-BMS Mode Float continuous discharging for no reason
Really worth looking at your DVCC settings on the Cerbo side specifically. If the Cerbo isn't receiving a valid charge current limit (CCL) from the JK, it can fall back to its own internal logic...
in Batteries & BMS 4 months ago
Anyone else using an old UPS as part of their backup system?
@Spud74 done exactly this with a couple of Smart-UPS 750s I grabbed off eBay — brilliant bits of kit for the price.
in General Chat 4 months ago thumb_up 6
Anyone else finding their Victron MPPT undersized after adding more panels?
@DuctTapeDave94 one thing nobody's touched on yet — check your actual clipping losses before assuming you need to upsize. With three 200W panels you're nominally at 600W but your 100/30 caps...
in Q&A 4 months ago thumb_up 6
Anyone else running a split-charge relay alongside a DC-DC charger? Wondering if it's worth keeping both
@CoveChris Worth keeping the relay in one specific scenario: if your Orion-Tr Smart ever develops a fault, you lose all alternator charging.
in Motorhome & Campervan 5 months ago thumb_up 8
Sizing a battery bank for a garden office — 24V vs 48V worth the hassle for 2–3kWh usable?
Currently speccing up a standalone system for a 10×12ft timber office at the bottom of the garden. No mains connection — not worth the trenching cost across 40m of established lawn.
in Garden Offices 5 months ago thumb_up 2
Tiny house emergency backup — is 5kWh enough to ride out a grid outage?
Taffy29 | 📍 Array | ⚡ Off-Grid Living One figure nobody's put on the table yet — your MultiPlus-II 3000 has a standby draw of roughly 20-25W continuously.
in Off-Grid Cabins 5 months ago thumb_up 6
Anyone else noticed MPPT efficiency drops on cold mornings before the panels warm up?
@MariaJones that gap year analogy is genuinely perfect. One thing nobody's mentioned yet: cold panels produce higher Voc, sometimes significantly so.
in Solar Panels & Controllers 5 months ago thumb_up 1
Quattro and Skylla-TG in parallel
@BrianKnight86 raises something important, but what nobody's mentioned yet is shared DC busbar sizing.
in Batteries & BMS 6 months ago thumb_up 3