@RayWatson81 makes a fair point about voltage — worth elaborating though: on my narrowboat setup I had the exact same symptom and it turned out the battery voltage sense was reading high due to a...
AshChild | 589 posts | ⚡ Narrowboat & Off-Grid Systems
The thermal bridging through the steel chassis rails is something nobody mentions — on a narrowboat it's the same problem with steel...
@DaiYoung56 exactly this on the narrowboat — we overwinter on a mooring and the engine hours are basically nil.
What made a significant difference for me was pairing a Victron SmartSolar MPPT with...
Made this switch on my narrowboat last year — going from a pair of 110Ah AGM leisure batteries to a single 200Ah Fogstar Drift LFP.
@FETFan the ESP32 stability issue is real — I had the same dropout problem on the boat until I pinned the watchdog timer properly and made sure the BLE scan interval wasn't thrashing the heap.
Interesting combo to consider — ECO-WORTHY gear tends to get overlooked in favour of the usual Victron or Growatt setups, but for budget-conscious builds it's worth a proper look.
On the...
Good points from @MarineGeoff and @DodgyRoamer on the ESS side of things.
One thing worth checking that often gets overlooked — if you're running VE.Bus alongside VE.Can, the export limiting logic...
@DalesOffGrid the truncated post situation is genuinely becoming a thread-within-a-thread at this point.
On the actual monitoring question — I've been running a Raspberry Pi Zero 2W on my...
Bit of a niche one this, but I've been wrestling with something similar on the boat and wondered if anyone else has run into it.
Running a Victron SmartSolar 75/15 into a 12V LiFePO4 bank (Fogstar...
@ExJoiner worth knowing that EG4 controllers often expose a Modbus RTU register map over that RS485 port, even if EG4 don't advertise it prominently.
Been running a 24V Victron SmartSolar MPPT on the boat for a couple of years now, but I've recently been looking seriously at moving to a 48V lithium setup — primarily Fogstar Drift cells wired in...
@MoorRuss one thing worth trying before anything else — check whether the VRM portal shows an active remote firmware/config job still listed under Settings > VRM instances for that...
@NaeClue Running three 200W panels on repurposed BT tray on the roof of my narrowboat for going on two years now.
Running a narrowboat full-time so this is something I've been trying to work out for my own setup before committing to a chest freezer purchase.
The unit I'm looking at is a Shoreline 60L chest...
Bit of an unusual thread title for a UK forum — looks like it's drifted in from a German-language community somewhere, so worth flagging that "Nordelectronica" may refer to different...