Has anyone actually calibrated their Victron BMV against a clamp meter long-term?
Been running a BMV-712 on my boat for about 18 months now and I'm increasingly suspicious the SOC drift is worse than Victron's spec suggests.
in Monitoring & System Design 3 days ago thumb_up 6
Victron MPPT 100/30 showing "absorption" all day — panels barely producing anything?
@MartinParker64 Something nobody's mentioned yet — check your battery temperature compensation settings.
in Solar Panels & Controllers 3 weeks ago thumb_up 6
Anyone else running a Renogy DC-DC 40A alongside a leisure battery bank? Getting odd readings
The DCC40S has a peculiar behaviour when the alternator output drops during low-RPM idling — it can cause the charger to cycle in and out of bulk mode repeatedly, which shows up as erratic voltage...
in DC-DC Chargers 1 month ago thumb_up 7
Anyone else had their BMS cut out in cold weather? Sharing my findings
Over winter I had my 200Ah Fogstar Drift LiFePO4 go into low-temperature protection twice while aboard — once at around 3°C ambient inside the boat's battery compartment.
in Batteries & BMS 1 month ago thumb_up 6
Anyone else running a static caravan on solar + lithium and slowly losing their mind?
@MasterWanderer Three months of overcast is genuinely brutal on a static — the load profile is all wrong for it.
in Off-Grid Cabins 1 month ago thumb_up 5
Does anyone know if a Victron SmartSolar 100/30 can handle two separate battery banks without a combiner?
The SmartSolar only has a single battery output terminal, so no, it can't natively charge two isolated banks simultaneously.
in Q&A 1 month ago thumb_up 9
Anyone else finding their MPPT controller wildly overestimates battery SOC in winter?
@SophieClark this is a well-documented quirk with voltage-based SOC estimation on LiFePO4 in cold conditions.
in Solar Panels & Controllers 1 month ago thumb_up 1
Anyone else had grief with MPPT controllers draining batteries overnight?
BreezyHermit | Posts: 1,204 | Location: Array Something nobody's mentioned yet — check whether your VE.Direct or Bluetooth module is staying active overnight.
in Solar Panels & Controllers 1 month ago
Anyone else running a cheap Chinese MPPT off a single 100W panel? Sharing my numbers
@Foggy95 I ran a nearly identical setup on my boat for about eight months as a backup charging source — single 100W poly into a £12 eBay MPPT, 110Ah leisure battery.
in On a Budget 2 months ago
EG4 Flex boss 18 Max PV input Voltage = 600VDC? Is that the total for the entire inverter or is that per Mppt line in? I am confused.
@Smithy98 string design is where people come unstuck, particularly when mixing panel counts across MPPTs.
in Inverters & Chargers 2 months ago thumb_up 4