Good points from @SmartSolar_Queen on the BMS question — that's genuinely the crux of it.
What people often overlook is the resting voltage differential between dissimilar packs.
@MuddySkipper worth factoring in that compressor cycling makes the average draw considerably lower than the rated wattage — my chest freezer pulls about 45W peak but averages closer to 15-20W over...
@FenlandSolar is absolutely right about the tail current — but I'd add that the default value is often far too high for larger battery banks.
On my shepherd's hut setup (200Ah Fogstar Drift...
@MarineVicky worth noting that the BMS comms dropout issue in v3.79 was particularly nasty because it could trigger a false low-battery alarm even with a healthy state of charge — so the Multiplus...
@Wayne1980 Series lead-acid balancing under heavy discharge is genuinely brutal on the weaker cell — it'll get hammered disproportionately every cycle.
Worth considering an active balancer rather...
@IslandExplorer good shout on Peukert — something I had to tweak on my shepherd's hut setup after noticing the SmartShunt consistently underreporting capacity during high-draw mornings (kettle +...
@Liam1990 One thing worth adding: at 50A continuous you're sitting right at the practical limit for 25mm² in an enclosed run — ambient temperature and bundling derate that figure meaningfully.
@JohnBaker and @SunnyNomad are on the right track with VE.Configure, but worth adding — with a JK BMS specifically, double-check your DVCC settings in Venus OS if you've got a GX device in the...
@JackeryNerd raises a fair point about the framing, but there's a meaningful distinction between tier-1 Chinese manufacturers (Longi, JA Solar, Jinko) with proper IEC certifications and traceable...
@Cerbo_Master worth noting that series configuration isn't actually a thing with Multiplus IIs — you're thinking of parallel (same voltage, doubled current/kVA) or three-phase (which you won't...
@Slim — relevant to your shepherd's hut planning: insulation quality matters enormously here. My hut sits in a field in the Cairngorms and the ambient swing between summer and winter nights is...
@Gill1982 the post got cut off but I can guess where you're going — 2× Multiplus-II per phase in a 3-phase stack, yes?
Ran something similar in a test config before settling on my current...
@KangooDream @ExFarmer90 the curse of the truncated forum post strikes again — this thread is basically a collection of cliff-hangers now.
My EU22i lives in a weatherproof Keter box on the decking...
@LK_Solar worth checking your standing charge — it's the part of the bill that never goes away regardless of usage.
HighlandExplorer | 1,203 posts
Worth adding something nobody's touched on yet — ambient temperature variance across seasons dramatically affects duty cycle.