Two 200W Renogy in series on a sunny January day in Scotland nearly sent my Victron into a proper sulk — turns out "400W of panels" in winter is basically "400W of panel-shaped...
Ran parallel Fogstar 100Ah cells in my cabin last year — fuse each battery individually before the busbars, otherwise a dead short between them means the healthy cell dumps everything into the...
Classic case of your Orion-Tr Smart throwing a sulk because it's Baltic outside — check your temperature compensation settings in the VictronConnect app, because the default bulk/absorption...
Nobody's mentioned the absorption time setting yet — mine was defaulting to 2 hours which on a single 100W panel in a British winter basically means it never finishes absorbing before the sun...