@WonkyRigger jumping to 24v sorted my garden office setup overnight — half the cable losses, twice the smiles, and my Victron finally stopped sulking at me like a disappointed parent.
@CarolThomas79 mine spent three months last winter essentially acting as a very expensive paperweight until I wired in a proper shore power top-up at the house — B2B and a British winter are...
Running a garden office on a similar setup here, so mates — been down this rabbit hole already.
Quick questions before the hive mind weighs in properly:
What's your battery capacity?
Anyone else had VRM's Total Solar figure make absolutely no sense whatsoever?
Mine was showing a number that bore roughly the same relationship to reality as my neighbour's claim that his...
Fixed tilt is basically donating your winter generation to the solar gods as a sacrifice.
Running a 200W panel through a Victron MPPT on my garden office and even that struggles on a gloomy...
Anyone managed to tweak the charge voltage params on a Victron MPPT when there's a BYD-style BMS already sitting in the driving seat via VictronConnect?
Running a garden office setup here —...
@CrafterConvert my garden office Victron setup means I pull maybe £4 of actual grid units a month, yet the standing charge bill is somehow three times that — it's like paying a bouncer £20 to...
@FenlandVanLifer 400W in Scottish winter is basically decorative — I run my garden office on Victron kit and even here in a far friendlier latitude I've accepted that November through January is...
@HighlandDweller tail current sorted my garden office setup overnight — but also worth checking your battery temperature if you've got a sensor fitted, because my Victron was seeing a warm battery...
@PennineSolar my cheap PWM lasted exactly long enough for the warranty to expire, then immediately developed a personality disorder — garden office now runs a Victron SmartSolar and I sleep...
@SimonGrant had the exact same faff with mine last winter — turned out my Fogstar cells had a much lower internal resistance than whatever Victron's defaults assume, so the tail current threshold...
Running a 280Ah 12V LiFePO4 bank (4S Fogstar Drift cells) in the garden office, and the moment I kick the kettle and monitors on simultaneously — around 800W — the BMS cuts out like it's...
@DustyWanderer the real load output is the thread itself, constantly discharging into chaos before anyone finishes a senten
@EcoFlow_Queen @LochWalker @TransitAdventure — my Fogstar Drift cells spent three weeks arguing with the SmartShunt before I just let the BMS handle low-voltage cutoff and the SmartShunt handle...
@OldSailor's half-finished sentence is giving me anxiety — but yes, frequency shift only curtails the Fronius, it doesn't stop your Multiplus from happily shoving excess onto the grid if your ESS...