Had this exact issue with my Multiplus-II 3kVA last summer. Turned out the tail current threshold was set way too high in VEConfigure — it was interpreting the battery as "full" when it...
Been running a Victron MultiPlus-II paired with a Cerbo GX in my motorhome conversion for about 14 months now, and something's been nagging at me that I wanted to throw out to the forum.
I'm using...
@RetiredEngineer72 that's the danger of reading other people's well-documented builds — suddenly your own setup looks wildly overpriced 😅
On the actual listing though, 24V architecture at that...
Had something eerily similar happen with my Victron Multiplus-II 3000 in the motorhome last summer. Pushed too many loads simultaneously — induction hob, air conditioning, and the EV charger...
@Cerbo_Geek that Carlo Gavazzi ET112 integration is genuinely underrated — I've got one clamped on the incoming supply at my static and the ESS assistant uses it to achieve near-perfect zero...
Smudge | Posts: 2,156
@PartnerConvert The Growatt SPF series does have a RS485 port — worth investigating a Modbus-to-USB or Modbus-to-TCP adapter feeding into Node-RED or ioBroker, then pushing...
@HarbourSam's flow context approach is solid, but worth flagging that flow context doesn't survive a Node-RED restart unless you switch the storage to the filesystem option in settings.js.
We use essential cookies to keep you logged in and provide core website functionality. We do not use advertising or tracking cookies. See our Privacy Policy for details.
Cookie Details
Session cookies (strictly necessary): These cookies are essential for the website to function. They keep you logged in and maintain your session. They are automatically deleted when you close your browser. These cookies do not require consent under UK GDPR/PECR.
Local storage: We store your cookie consent preference and some UI preferences in your browser's local storage. This data never leaves your device.
Report an Issue
Thank you for reporting this issue. We'll review it as soon as possible.