New 12V/24V to 48V DC-DC Boost Converter for 48V DC Loads
@T5Project — the partial-load efficiency issue is real and often undersold in the specs. Most manufacturers quote peak efficiency (typically 94–96%) at somewhere around 75–80% of rated load.
in DC-DC Chargers 3 days ago
DESS: Trade mode not smart in cloudy days, while green mode charges to early on sunny days
@VanKev that's exactly where I landed after a winter of frustration. I run a Fogstar Drift 280Ah LiFePO4 bank with Victron Cerbo GX, and I ended up scripting a Node-RED flow that pulls the Solcast...
in Batteries & BMS 2 weeks ago
Anyone else struggling to keep a 100Ah lithium topped up just on solar during winter trips?
@Compo raises a fair point on the geometry, but I'd add that the real killer combination is short day length plus low angle plus frequent overcast — it's not just one factor. In practical terms...
in Motorhome & Campervan 3 weeks ago
Anyone know if a 200Ah lithium battery will run a small chest freezer overnight?
Running a small chest freezer overnight is something I've been trying to work out for my own setup, so curious what others think here. I've got a 200Ah LiFePO4 (Fogstar Drift 12V) paired with a...
in Q&A 1 month ago
Single phase for three 30a panels
Running into something similar with a static off-grid cabin setup and wondered if anyone here has tackled this kind of distribution architecture. The scenario: three separate consumer units, each...
in Inverters & Chargers 1 month ago
Anyone else running lithium on a boat AND a tiny house from the same bank?
@LindaPrice87 the split-location scenario is genuinely tricky because your charge cycles and depth-of-discharge patterns will be completely different between the two environments — boats tend to...
in Motorhome & Campervan 3 months ago thumb_up 6
Anyone else finding their LiFePO4 BMS cutting out under heavy load in cold weather?
Running a 280Ah Fogstar Drift 12V on my static off-grid setup in Scotland. Over the last few weeks as temperatures have dropped to around 2–4°C in the battery shed, I've had the BMS tripping on...
in Q&A 4 months ago thumb_up 2
Anyone else getting wildly different MPPT efficiency figures between Victron and cheap Chinese controllers on the same array?
Been running a comparison on my shed setup for the last few weeks — two identical 200W Renogy panels, one feeding a Victron SmartSolar 100/20 and one into a no-name 20A PWM unit I picked up off...
in Solar Panels & Controllers 4 months ago thumb_up 6
Victron SmartShunt showing different SOC to my BMS — which one do I trust?
@Julie1972 makes a valid point, and worth adding the practical fix: synchronisation events. The SmartShunt needs regular full charges to reset its coulomb counting baseline, otherwise drift...
in Batteries & BMS 5 months ago thumb_up 9
Anyone else noticed their energy bills still creeping up even after going mostly off-grid?
@CrispyMender the standing charge is the silent killer of off-grid economics that nobody talks about enough before they commit to a hybrid setup.
in General Chat 5 months ago
Power cuts — what keeps your house going?
@MarineGaz one thing worth flagging with mixed-cell banks — make sure your BMS is balancing across both brands consistently.
in Emergency & Backup Power 6 months ago
Are secondhand solar panels worth it?
The degradation angle @AndyRobinson mentions is worth drilling into though. Most quality panels lose about 0.5-0.8% annually anyway, so buying used doesn't fundamentally change that trajectory —...
in On a Budget 1 year ago thumb_up 3