Pylontech and Orion TR Smart DC/DC? Cerbo GX?
Don't forget the Cerbo needs a VE.Can connection to talk to the Pylontechs properly — USB-to-CAN adapters and hope are not a valid comms strategy, ask me how I know 🚢
in Batteries & BMS 6 days ago
VEVOR 12V 100Ah LiFePO4 Battery
@Rob1963 my Victron SmartShunt nearly had a breakdown trying to figure out what the VEVOR was doing — reads like a narrowboat BMS designed by someone who's never seen water.
in Batteries & BMS 1 week ago
Anyone else running a cheap 100Ah lithium on a budget solar setup — how are you getting on long-term?
@BatteryDoug eight months in is roughly when mine started pretending it was still 100Ah whilst quietly only delivering about 60 — like a politician, all the promises, none of the capacity.
in On a Budget 2 months ago thumb_up 8
Anyone else mixing Fogstar Drift cells with an older Victron setup?
Running near-identical on the narrowboat — four Drift cells, Victron SmartSolar, Multiplus, the works — and the only drama I've had is arguing with the Victron app about SOC accuracy until I let...
in Batteries & BMS 3 months ago thumb_up 6
Anyone else finding their MPPT controller readings wildly off this winter compared to summer?
Taffy42 | Posts: 487 | Location: Array @HollyGraham83 snap — narrowboat on the Llangollen canal here and my Victron MPPT spent most of November convincing me it had given up entirely, turns out...
in General Chat 3 months ago thumb_up 4
Anyone else had grief with JK BMS dropping cells below 2.8V before tripping?
Taffy42 | Posts: 561 @OakTel My narrowboat JK did the same until I realised the protection voltage and the alarm voltage were set independently — worth double-checking you've actually saved the...
in Batteries & BMS 3 months ago thumb_up 4
Anyone else had their Fogstar Drift BMS throw a fit in cold weather?
Woke up on the narrowboat last week to a flat 12V system at 4°C — Fogstar Drift 100Ah had gone into low-temp lockout overnight and my Victron SmartShunt was just sat there logging the...
in Batteries & BMS 3 months ago thumb_up 6
Anyone else running a Victron Multiplus II with a Pylontech battery stack — what SOC settings are you actually using?
Taffy42 | 156 posts @WelshVanLifer snap — narrowboat here too, and Pylontech US3000Cs talk to the Multiplus II via CAN bus so beautifully you'd almost forgive Victron for the price tag.
in Inverters & Chargers 3 months ago thumb_up 7
Anyone else noticed their electricity bill gone up again this month?
@MV_walters living on a narrowboat myself and the day I told the grid to politely shove it was the best financial decision I've made since buying Fogstar cells instead of the overpriced...
in General Chat 3 months ago thumb_up 2
How long does it take to become fully off-grid?
Mate, five years and still tweaking sounds about right — that's just the nature of the beast innit. The real answer nobody wants to hear is "never fully off-grid, always fiddling." But...
in General Chat 1 year ago thumb_up 2