AlanPalmer57 | ⭐ Regular
@SaltyHiker One thing nobody's mentioned yet — what angle is your panel mounted at?
@RetiredEngineer86 @BatteryBarry genuine question — how much of that Victron ecosystem advantage actually matters day-to-day vs. just being nice to have?
@MountainBarry @Wayne1996 — did either of you check the BMS logs before the cutout? I'm having something similar with my setup and wondering whether the over-voltage protection threshold on the...
Has anyone tried using a SmartShunt alongside the JK BMS and just pointing the Cerbo at the SmartShunt for SOC whilst keeping the BMS connected purely for cell-level protection data?
That's the...
Just picked this up for £35 from a bloke about 20 miles away — no brand markings I can recognise, just a sticker saying "200W 24V" and what looks like it might be a Chinese OEM panel...
Has anyone actually done this successfully with a single MPPT controller, or does it always end up needing two separate units?
My situation: I've got a 400W array on the shed roof and I'm trying...
@WattHelen genuinely curious what the rabbit hole was though — is the actual question about whether the Multiplus needs clearance above, below, or both sides for proper airflow?
Been following this thread with interest because I had something similar last year with my Honda EU22i — kept dropping out after about 20-30 minutes of runtime, almost like it was hitting a...
Just upgraded from a cheap PWM controller to a Victron BlueSolar MPPT 75/10 and trying to get my head around the default charge profile it ships with.
From what I can gather, it comes...
@BatteryRay yes, same issue here with my setup. Worth checking whether your Fogstar has the low-temp charging cutoff or the low-temp discharge cutoff triggering — they're quite different problems...
@KenCrane interesting — I've been eyeing up the EPever range myself. Quick question: are you running it directly into a Victron inverter or just straight to batteries?
Picked up four 100Ah Fogstar Drift LiFePO4 cells back in April to build a 12V 200Ah battery (2P2S). Been running them with a Daly 100A BMS and a Victron SmartSolar 100/30 on a 400W roof...
@Spud curious what you're using as the isolation switch — is it a manual rotary cutoff or have you automated it somehow?
AlanPalmer57 | 43 posts
Had almost identical setup last winter and the PWM limitation really hit me hard around December/January.
AlanPalmer57 | Posts: 43
Watching this thread closely — I've got a Fogstar Drift 100Ah in a static shed setup and noticed similar things over winter.
One thing nobody's mentioned yet: what voltage...
in Q&A
5 months ago
thumb_up 8