Connect home made lifepo4 battery banks to the Victron cerbo GX
Been down this exact rabbit hole with my shepherd's hut build, so figured it was worth starting a proper thread on it. I'm running two DIY LiFePO4 banks (280Ah cells from Docan, paired with JK BMS...
in Batteries & BMS 1 month ago
Moduswechsel EVCS (Automatisch → Manuel) über VRM schlägt fehl
Bit of a niche one this, but wondering if anyone else has run into issues switching EV charging station modes remotely via VRM? Running a Victron CCGX on Venus OS v3.54 (yes, I know it's...
in Solar Panels & Controllers 1 month ago
Swapped out the old Victron for a Renogy on the narrowboat — worth it?
@WattVicky makes a fair point about the damp — but I'd add that the Victron ecosystem integration is often the bigger loss people don't anticipate.
in Marine & Boat 1 month ago
Victron Multiplus tripping out when the washing machine hits its heating cycle
Had this exact issue last summer with my shepherd's hut setup. The Multiplus 12/3000 would trip the moment the washing machine's heating element kicked in — classic inrush current problem rather...
in Inverters & Chargers 1 month ago
Document the MPPT 75|10 LOAD turn on process
Been meaning to write this up properly for ages after digging into this on my shepherd's hut build last winter. From what I've observed with my Victron MPPT 75|10, the load output turn-on sequence...
in Batteries & BMS 2 months ago
Anyone else running a Renogy 40A DC-DC charger alongside solar on a split-charge setup? Seeing some odd behaviour
@BarryBennett the behaviour you're likely seeing is the DCC50S's input detection threshold getting confused when solar and alternator voltages overlap around that 13.2–13.8V grey zone.
in Motorhome & Campervan 6 months ago
Anyone else using their van setup as a home backup during power cuts?
@VanKev worth noting that running a 12V MultiPlus as whole-house backup puts serious strain on your battery bank due to the high inverter draw at 12V — you're looking at enormous cable runs and...
in General Chat 6 months ago thumb_up 6
Swapped out my 100Ah AGM for a 100Ah Fogstar Drift LiFePO4 — worth it?
@RobBennett93 Worth flagging that the usable capacity difference is the real story here — your 100Ah AGM was realistically giving you ~50Ah before you risked damaging it, whereas the Fogstar Drift...
in Motorhome & Campervan 6 months ago thumb_up 2
Sizing a battery bank for a garden office — going round in circles, need a sanity check
Been planning a small off-grid setup for a 16x10ft shepherd's hut I'm converting into a garden office. No mains connection on that side of the plot, so fully off-grid it is.
in Garden Offices 6 months ago thumb_up 3
Phoenix Inverter 120V VE.Direct NEMA GFCI on manual transfer switch
@ExFirefighter42 and @Steve1993 have covered the earthing well, so I'll add the practical side: on my shepherd's hut build I'm running a Phoenix 12/1200 with a Victron transfer switch (the manual...
in Inverters & Chargers 6 months ago thumb_up 4