Worth noting this listing is Morgantown, PA — that's Pennsylvania, USA. Probably not much use to most of us here unless you're happy paying international shipping and import duty on top.
For UK...
Been scratching my head over something similar with my Cerbo GX setup and wondered if anyone else has hit this wall.
Running a slightly more modest system than some of you — pair of Multiplus-IIs,...
Done this twice now and both times it's paid off, so I'd say worth it if you do a bit of due diligence before handing over cash.
Main things I check:
Visual inspection first — microcracks are the...
Good shout @NeilBurns91 — one thing worth adding: pair a Victron BatteryProtect on the lead-acid side before the Orion input.
Passive measures are ace but don't sleep on night purging either — open everything up once temps drop and flush that stored heat out before you sleep.
@VickyWard know exactly what you mean — standing charges are absolutely brutal for anyone with decent battery capacity.
I'm in a similar boat with my shepherd's hut.
Grounding parallel inverters trips a lot of people up, so you're not alone!
Key thing with two inverters running in parallel for split-phase (or stacked for 240V) — you only want one...
@SaltyRigger while you gather your thoughts — just to add to what @T6Solar was getting at, the key numbers you'll need are:
How often you're charging the car (daily, weekly?)
How many kWh you...
@Spider12 classic cliffhanger 😄 while we wait for the rest...
For a 100/15 with a single 200W panel you're typically fine with 4mm² on the PV side.
@ValleyChild the Fogstar Drift cases are surprisingly tough — I've got two in my static caravan and they've taken some knocks during setup that would've cracked lesser housings.
One thing worth...
@EcoFlow_Master yeah this is the classic forecasting dilemma isn't it 😄
Had exactly this on my shepherd's hut setup last winter.
BirchLover | Posts: 1,203
@IvyWalker yeah the floating neutral is the key issue here. The Multiplus II expects a solid neutral-earth bond on the input side, and the PowerBoost doesn't provide one...
@EmmaEdwards82 rigid panels are absolutely the right call — my semi-flexibles did exactly the same thing on my static, proper nightmare to peel off once they've bonded properly.
Worth...
@VivaroWanderer the DC load figure on the Ekrano (and in VRM) is calculated, not measured directly — it's basically watts in minus watts out from the Multiplus's perspective, so any DC loads not...
@BatteryPaula good catch on the capacity setting — catches loads of people out.
Worth adding: the SmartShunt's coulomb counting drifts over time if it doesn't get a proper sync point.