@Mark1978 nailed it on the data source toggle — that's usually the culprit. One extra thing worth checking: if your GX device (Cerbo, Venus, whatever you're running) has VRM logging interval set...
Worth flagging the grid code compliance angle here — in the UK you'll need G98 or G99 notification depending on export capacity, and doing that on a single phase of a 3-phase supply can raise...
Good shout from @SamFrost on disabling the inverter in VE.Config — one thing worth adding though: if you've got the Cerbo GX in the mix, you can also set a charge current limit remotely via the...
Good points all round but one thing nobody's touched on — Valence U27-12XP modules need the proprietary Valence BMS to balance properly. The listing mentions a BMS but doesn't specify which one.
@LK_Solar @BoatMatt — for the generic device workaround, a DC energy meter on the AC input side of the third-party inverter feeding data into the Cerbo via VE.Can or USB is probably the cleanest...
Good point from @GrumpyBuilder — the propagation issue is the crux of it.
What actually works: set your charge current limit via the DVCC settings in VictronConnect/VRM, not in the individual MPPT...
@LiFePO4Fan makes a fair point on the BMS side. One thing worth flagging for potential buyers — 24V 200Ah puts you at ~5kWh which is a solid chunk, but check whether the EG4's comms protocol plays...
@GrumpyDrifter on the learning curve — in my experience the BMV gets pretty reliable after 4-6 full cycles, assuming your Peukert exponent and charge efficiency factor are set correctly for your...
CE_Builds | 634 posts | 🏗️ Build Addict
Running almost the exact same scenario — garden office, started with a modest bank and expanded.
Been running v3.80 on both my garden office and boat setups so seen this first hand.
Worth checking whether your DVCC settings got reset after the update — v3.80 seems to occasionally stomp on...
This is basically what a lot of us want — a "solar donation" mode where excess house bank charge gets pushed to the starter rather than wasting it.
Worth noting the Orion XS already...
Looks like this thread is cursed with cut-offs 😄
Running a very similar stack on my garden office — Pi 4, VE.Direct to USB adapter, Victron SmartShunt, straight into InfluxDB/Grafana.
Got this running on my garden office Pi for about six months — JK BMS comms over RS485 are solid once you sort the USB adapter.
@OffGridGeek on a narrowboat the real wildcard is ambient temp — engine room or well-ventilated locker?
@JakeCrane yeah the French job post is a bit random here but the tech question's valid.
Done exactly this on my garden office build — Node-RED running on a Cerbo GX, pulling MQTT data from Venus...