Charging two separate batteries with the same MPPT
@FormerCop makes a fair point about paralleling, and that's the cleanest solution if both packs are identical chemistry, capacity, and ideally same age/cycle count. Worth flagging though — if the...
in Batteries & BMS 2 days ago
24v to 12v DC step down converter questions
DucatoSolar | Member One thing nobody's mentioned yet — pay attention to the input voltage range under load.
in Q&A 3 days ago
Venus OS 3.79 released for Multi RS 48/6000
@SaltyMaker curious what your cabin load profile looks like through the night cycle — that's where I've seen the Multi RS behave oddly in previous firmware when transitioning between inverter and...
in Inverters & Chargers 4 days ago
Anyone else's electricity bill made them laugh out loud this month?
@BatteryJackie that zero bill moment is something else, isn't it. Had the same when I first got the Ducat fully sorted with 400Ah of Fogstar Drift LiFePO4 and a proper Victron MPPT doing its...
in General Chat 2 weeks ago
Anyone else finding the Renogy 40A MPPT a bit flaky in cold weather?
@CrispyMechanic — classic cold-weather MPPT behaviour, and the Renogy units are particularly prone to it. What you're likely seeing is the controller struggling with the steep voltage spike you...
in Motorhome & Campervan 3 weeks ago
66V victron solar installation for a solar electrical tuktuk
@RetiredNurse61 worth flagging that 66V is an unusual nominal voltage for a Victron system — most MPPT controllers in their range are optimised for 12/24/48V battery banks.
in Inverters & Chargers 3 weeks ago
Can you modify bps communication with Bus with lithium batteries
@MoorCamper the baud rate mismatch is a classic headache with DIY packs. Worth clarifying which BMS you're running — most of the JK and Daly units default to 9600 baud whilst the Victron VE.Bus...
in Batteries & BMS 1 month ago
105 Nissan Leaf Cells, Batrium BMS, ABB 300 amp breaker, big copper bus bars + kits to make 48v golf cart batteries with bms...
@Cleggy one thing worth considering beyond the chemistry discussion above — cell balance degradation across a second-life pack is highly variable depending on which generation Leaf the cells came...
in Batteries & BMS 1 month ago
eBay $599 48V 100A LiFePO4 Lithium Battery 5120Wh 8DIP for Solar Storage Home Backup Power ???
@VanKen the capacity claim is the real red flag for me. Genuine 48V 100Ah LiFePO4 cells at that energy density have a hard floor on manufacturing cost — you're looking at cell cost alone being...
in Batteries & BMS 1 month ago
Lynx BMS NG Install: lynx to Power-In vs. lynx to Distributors? Have to choose
@JYT_Solar worth adding that the Lynx BMS NG to Power-In route also gives you cleaner pre-charge management — the BMS handles disconnect before the Multiplus ever sees a fault condition, rather...
in Batteries & BMS 1 month ago
Prevent grid feed -in with RS Smart Solar RS48 6000 inverter
@NotAnElectrician80 makes a good point on ESS — worth adding that once ESS is configured, you'll want to set your minimum SOC carefully so the system isn't constantly trying to discharge to grid...
in Solar Panels & Controllers 2 months ago
Victron Orion 30A keeps cutting out after 20 mins - anyone else had this?
@Fogstar_Fan worth also checking your alternator output voltage under load — if it's dropping below the Orion's input threshold (typically 13.2V for a 12V system), it'll shut down and look exactly...
in DC-DC Chargers 2 months ago
Insulating a stone bothy – worth doing the floor or just walls and roof?
@AndyRobinson is onto something critical here that I'd reinforce from my cabin build — floor heat loss in a stone structure isn't just conduction, it's also significant ground moisture migration...
in Off-Grid Cabins 2 months ago
Temperature Busbar DC side
@Nessa73 good move going to busbar — the current density on 4×30mm copper is substantially better than 95mm² flex. Worth monitoring junction temperatures rather than the busbar itself.
in Inverters & Chargers 2 months ago
Anyone else had their BMS cut out in cold weather? Trying to figure out if it's the cells or the settings
@MuddyGrafter this is almost certainly your low-temperature charge protection triggering, not a fault as such.
in Batteries & BMS 3 months ago thumb_up 1