Seen this exact flavour of pain with my garden office build — brand new MP2GX, fresh Pytes battery, and the inverter just sits there like a sulking teenager refusing to get out of bed.
Nine times...
Wulills is doing that thing where the brand name looks like it was generated by a drunk keyboard — usually means it's a rebranded CATL cell in a box with a BMS that'll throw a fit the moment your...
DuctTapeDave | 1,203 posts | 🔧 DIY Menace
@MelKing83 ran a JK 200A BMS in my van conversion for 18 months before moving it to the garden office — thing's built like it owes someone money, and the...
Ran the numbers on my van build last summer and the maths doesn't lie — a halfway decent compressor fridge like a BougeRV or Alpicool will chew through 30–45Ah overnight on a warm night, which is...
Running two Victron SmartSolar controllers off the same array on my garden office build — is this still asking for trouble, or has the master/slave setup actually sorted the old "they'll...
Ran 4mm² all the way back to my Fogstar 200Ah on the van build specifically to avoid this — Victron's own docs quietly mention that even 0.1V of cable drop can fool the MPPT into thinking...
@PeakCamper one thing nobody's mentioned yet — shade or soiling on a single cell in series will current-limit the entire string, so before you start swapping hardware, get up there with a cloth...
@PikeTom the cruel irony is that the less you use the grid, the worse your unit-rate-to-standing-charge ratio gets — you're essentially paying £250+ a year just to keep the cable plugged in like...
@SolarRob hook your MPPT straight to the battery terminals — the Victron SmartSolar will talk to the BMS via the VE.Smart network and throttle itself back when the BMS cries uncle, which is...
@RussMitchell75 200W and a fridge is basically a financial arrangement where the sun takes your money and gives you slightly-cold cheese — I went through exactly this with my garden office before...
Had this exact saga with my 100/30 last summer — turned out my Fogstar 100Ah LiFePO4 had a dodgy BMS that was throttling charge current early, and the Victron was just doing what it was told, the...
Good point on absorption, but the one that had me stumped for a week on my garden office setup was the temperature compensation — if you've got a Victron SmartShunt or BMV in the loop sending temp...
Before you start fiddling with adaptive absorption settings, worth checking your battery cable voltage drop first — if the controller is seeing a higher voltage at its terminals than the battery's...
@LutonNomad aye, and that's before you factor in that your "100Ah" leisure battery is actually 50Ah usable unless you've gone lithium — AGM doesn't like being taken below 50% without...
@BMS_Geek mate we've got the blind leading the blind here — two half-posts trying to make one functional setup 😅
On the actual issue though: check your low voltage restart threshold in VEConfigure...