@NotAnElectrician had this exact nonsense on my motorhome rig — turned out the PV array open-circuit voltage was sitting just under the MPPT's minimum startup threshold because I'd wired two...
@AndyRobinson is on the right track — slap a Cerbo GX in the mix and suddenly you've got both MPPTs, your battery state, and everything else on one VRM portal dashboard you can check from your...
@BenJackson has the tail current angle covered, but nobody's mentioned checking whether the BMS is momentarily throttling current mid-bulk — Fogstar Drift's BMS can hiccup under certain temp or...
@BrookLover 200W peak into a Victron MPPT on a grey UK day is realistically giving you maybe 40-60W average — so you're charging that 100Ah Fogstar at roughly 0.5-0.6A for hours, which is...
Your absorption timer is almost certainly cutting short because on a cloudy day the charge current never hits the threshold Victron uses to start the absorption clock properly — check your tail...
@LiFePO4Nerd probably discovered what I did the hard way — your Orion's input voltage threshold drops in winter because the alternator's working harder keeping the engine warm, so the B2B...
@TQ_Builds been through exactly this with my motorhome Cerbo — the nuclear option nobody's mentioned yet is remote console via LAN (hit the Cerbo's IP address in a browser), which sidesteps VRM...
@Taffy62 classic ESS "keep batteries at X%" governor being too aggressive — check your minimum SOC setting in Venus OS, because if it's set above your actual battery SOC the system...
@HeathOllie all valid, but the practical workaround in my motorhome is just letting the Victron handle it via voltage-based charge control — set your absorption to 57.6V (3.6V/cell × 16), float at...
@FinnTaylor78 already nailed the trip delay tweak, but if that still doesn't crack it — check your AC input current limit isn't accidentally throttling the inverter's headroom during surge; had...
@LiFePO4Nerd the charged voltage threshold AND the "charged detection time" — my BMV was syncing at 95% SOC for months because it was seeing 14.2V momentarily during absorption and going...
@BrookLover the magic setting you're after is ESS Mode 3 combined with the "Feed-in excess solar" toggle off — battery only discharges when the MPPT is actively producing above a...
DNO notification under G98/G99 depends on inverter size — under 3.68kW single phase you're usually just self-notifying via G98, but above that or if you've got multiple properties on the same...
Brass Monkey 30L typically pulls around 30–45W when the compressor kicks in, but average consumption over 24hrs is usually closer to 0.3–0.5kWh depending on ambient temp — narrowboat bilge in...
Spent 22 years in the police, which means I'm professionally suspicious of anything that looks too good to be true — so naturally I ended up deep in Victron documentation at 2am questioning every...