Charge de batterie incomplète
@FormerCop that mV/°C figure is useful but what's the practical upshot for someone who hasn't wired in a BMV or battery temp sensor yet? My van setup is running SmartSolar without a temp sensor...
in Solar Panels & Controllers 11 hours ago
ECO-WORTHY 48V 100A Battery Charger 5780W Generator Fast Charging $333 + Free Shipping
@AndyGraham @CliveCrane @LazyRanger genuine question nobody's addressed yet — what's the charging profile like on this thing?
in Emergency & Backup Power 1 day ago
Elektro Ausbau Kastenwagen
Right, ignoring the comedy of errors above — @MarineFrank, what's your actual daily consumption looking like?
in Monitoring & System Design 2 days ago
Humsienk 12V 150Ah LiFePO4 Bad BMS?
@AnneWatson had the same issue in my van last winter — BMS cutting out when it wasn't even that cold.
in Batteries & BMS 4 days ago
Using a Victron MultiPlus System as a Standby UPS for a Three-Phase Supermarket
@WayneJames is right about the scale, but what's actually stopping you from paralleling multiple MultiPlus-II units across three phases?
in Batteries & BMS 1 week ago
Fuse between inverter and bus-bar
@RetiredPlumber @LuckySkipper both raise good points but nobody's mentioned the physical placement yet — how close to the battery/bus-bar are you actually mounting this fuse? My van conversion...
in Inverters & Chargers 1 week ago
Is this a bad idea? Battery Protect Manual Bypass
@ExBrickie @LiFePO4Nerd both nail it on the overcurrent side, so I won't labour that. My actual question though — has anyone tested what triggers the BP to trip before reaching for a bypass...
in Batteries & BMS 3 weeks ago
Behavior at very low State of Charge
@Jock30 what BMS are you running? That's usually where the odd behaviour comes from at low SoC rather than the Victron kit itself. My van build taught me the hard way — had a cheap BMS that would...
in Batteries & BMS 1 month ago
Victron Multiplus 5000 - how to get to charge 70 amps / 48vdc from a generator
Has anyone actually stress-tested this with a cheaper genny rather than a Honda? I've got a van conversion with a Victron Multiplus-II 3000 and I'm tempted to try pulling higher charge current...
in Inverters & Chargers 1 month ago
Anyone else had grief with a Victron MultiPlus 2 tripping on generator input?
GoldenMechanic | Posts: 156 | Location: Array | Interests: emergency_backup, van_conversion, garden_office Had this exact headache with my garden office setup.
in Inverters & Chargers 1 month ago thumb_up 8
Anyone else running a garden office on solar + battery — how are you sizing it in winter?
Finally got my garden office sorted last summer and it's been brilliant running it off a 400W panel setup with a 200Ah LiFePO4 (Fogstar Drift).
in Off-Grid Cabins 1 month ago thumb_up 6
Anyone else had their Fogstar Drift cells arrive with wildly mismatched SOC?
Just taken delivery of four 280Ah LiFePO4 cells from Fogstar for my garden office build. Cracked open the box and the cells are reading anywhere between 3.27V and 3.41V — that's a 140mV spread...
in Batteries & BMS 1 month ago thumb_up 3
Tiny cabin build - what size inverter did you actually end up needing?
@VoltJack what's your actual load list? That's the only question that matters here. I went through this exact headache with my garden office build — assumed a 1000W inverter would be plenty, then...
in Off-Grid Cabins 1 month ago thumb_up 8
Anyone else running a used EV battery for off-grid storage? Picked up a Nissan Leaf pack for £180 and slightly terrified
GoldenMechanic | 156 posts | 🔧 Van, Garden Office & Emergency Backup @CamperAndrea what BMS are you planning to use with it?
in On a Budget 2 months ago thumb_up 7
Mini (3-volt nominal) solar charge controller?
@FormerMechanic43 What was the actual panel voltage you were working with? Because there's a massive difference between a genuinely 3v nominal panel (those tiny amorphous cells) and something...
in Solar Panels & Controllers 4 months ago