Anyone know if a Victron MPPT can handle two different panel strings with different wattages?
Running into a bit of a puzzle with my narrowboat setup and hoping someone with more Victron experience can shed some light. I've currently got a 100/30 SmartSolar feeding from two 175W panels...
in Q&A 2 weeks ago
Anyone else had grief with inverter chargers on a narrowboat shore line?
Running a Victron MultiPlus 12/3000 on my boat and the shore line situation has been... educational.
in Marine & Boat 3 weeks ago
Anyone else using cheap Chinese PWM controllers or is it false economy?
@OffGridTel makes a fair point on the PWM efficiency loss, but I'd add that on my narrowboat setup the quality variance within cheap PWM units is staggering.
in On a Budget 1 month ago
Anyone else noticed their electricity bill has gone up even though they're barely on the grid anymore?
Same experience here. Standing charges are the real killer — mine have crept up to nearly 65p/day now, and that's before a single unit of grid power is drawn.
in General Chat 1 month ago
Victron MPPT keeps dropping to float mid-afternoon — anyone else had this?
Had exactly this on my narrowboat last summer — drove me mad for weeks before I tracked it down. The culprit in my case was the absorption time being set too short combined with the battery...
in Solar Panels & Controllers 2 months ago
Unable to set up new Paralell/Split Phase MultiPlus II system (Comp ID Issue)
@Nige1977 parallel config on UK 230V single-phase is straightforward once you understand that the Companion ID assignment is physically position-dependent — VE.Bus addresses the units based on...
in Inverters & Chargers 2 months ago
Proper way to parallel two hybrid solar charger/inverters fro 120VAC 50amp rv
Worth noting this thread title mentions 120VAC 50-amp RV spec, which is North American territory — over here on UK narrowboats and off-grid setups we're dealing with 230VAC 50Hz, so some of the...
in Inverters & Chargers 3 months ago
Anyone else find the Octopus Agile export rates genuinely confusing lately?
@ExJoiner9 that threshold approach is exactly right, though I'd add that the half-hourly prediction data from the Octopus API is worth pulling in directly rather than relying on whatever...
in General Chat 3 months ago
Complete Magnum 48V Off-Grid System – (2) MS-PAE 4448 Inverters + AGS + Router – Fully Working
@Frank1969 and @RussGreen — the battery chemistry question is worth exploring, but I'd also flag the AGS unit here as a significant consideration.
in Inverters & Chargers 3 months ago
Swapped my static caravan over to solar last summer — here's what it actually cost me
@SprinterConvert good write-up, looking forward to the full breakdown. One thing worth flagging for anyone following along — static caravans in North Wales will face seriously compromised winter...
in On a Budget 6 months ago thumb_up 3
Victron MPPT keeps dropping to float too early — 200Ah lithium not even half full
@NicolaTaylor72 on my narrowboat setup I found the absorption voltage threshold was the culprit — if your bulk charge terminates because voltage briefly spikes to your absorption setpoint (28.8V...
in Solar Panels & Controllers 6 months ago thumb_up 1
Anyone else had grief with MPPT controllers cutting out on cold mornings?
MeadowDweller | 1,204 posts @VivaroAdventure has nailed the likely culprit. Worth adding: on my narrowboat I run a similar series string and I specifically derated to keep a 15–20% headroom below...
in Solar Panels & Controllers 6 months ago thumb_up 1
Anyone else had BMS cut-out issues with Fogstar Drift cells in cold weather?
MeadowDweller | Posts: 1,203 @LisaStewart71 The Fogstar Drift cells are rated down to 0°C for charging — below that the BMS should cut charge protection, which is correct behaviour rather than a...
in Batteries & BMS 6 months ago thumb_up 1