@DailyWanderer yeah DVCC with mixed battery info is a bit of a rabbit hole innit. The Remote Console just aggregates everything so you lose visibility of individual cells pretty fast.
What I've...
@BurnBen classic voltage sag issue mate. The MPPT sees resting voltage and calls it 100%, but under a big load spike like an induction hob you're seeing the true internal resistance of the...
@TonyLee yeah been doing something similar for about a year. Running a Pi Zero 2W rather than a full Pi 4 — way lower power draw which matters when you're watching every watt.
I've got mine...
@BevJackson64 pretty sure it doesn't log thermal events natively, but if you've got a Cerbo GX or even the VictronConnect app open during a drive you'll catch the cutout in real time.
@GlenWard yeah thermal's almost certainly your culprit. Mine was doing the same thing on the A1 until I moved it out from behind the cab lining where it had zero airflow.
Victron recommend at...
Got a shepherd's hut project on the go and trying to figure out battery sizing before I pull the trigger on anything.
The hut is pretty modest — think weekend retreats, maybe the odd week here and...
The weak link problem is real with series strings — your 200W panel is basically getting dragged down to match the 175W ones in low light.
Picked up 4x 280Ah LiFePO4 cells from Fogstar last spring, built a 12V 280Ah bank with a Daly BMS. Summer was brilliant — barely touched 90% most days with the solar keeping up.
Come November...
@DaveMoore70 kettle's almost certainly your culprit mate. Even a "small" one is pulling 1000-1500W and the Drift's BMS can be touchy about sudden high-current spikes, especially if your...
Had this exact issue with my setup last summer. The thing people miss is usable capacity — your Fogstar Drift is great but you're realistically working with maybe 80Ah before the BMS gets twitchy,...
in Q&A
5 months ago
thumb_up 7
What @T5Build said about sensor placement is key — mine was tucked against the BMS board itself rather than actually touching a cell, so it was reading ambient not cell temp.
Been trying to get hold of some 280Ah EVE cells from Fogstar for about six weeks now. Every time they come back in stock they're gone within a day or two.
Just wired up a 200Ah Fogstar Drift 12V to my Multiplus-II 12/3000 and trying to nail down the charge profile.
Finally pulled the trigger on two 100Ah Fogstar Drift batteries wired in parallel for my Transit Custom build.
Been running 48V for three years now and it's genuinely the goldilocks zone. You get proper headroom for expansion without the cost and complexity of higher voltages.