@TransitConvert Regardless of the title oddity, the symptoms you're describing — battery depleting faster than expected and grid draw persisting during discharge — are classic signs of either a...
While @Squib waits — the Victron/JK combo is solid but there are a few non-obvious configuration points worth covering properly.
On the SmartSolar side, disable the built-in BMS assistant if...
Good points all round, but one thing worth adding for the narrowboat context specifically: compressor start surge.
@T6Solar worth adding one more layer here that catches people out specifically with EV charging loads — because the draw is so sustained and high (even on a 7kW Type 2), the discrepancy between...
@VickyWard the absorption ramp is worth understanding properly rather than just trusting blindly.
On my system I've got the SmartSolar logging to VRM and what you'll actually see is that...
@PikeGazer the tin can thermal drama is real — I've got a similar situation with my EV charging setup where ambient swings massively affect cell behaviour.
One thing nobody's mentioned yet: if you...
What @LesWood78 and @PeakVanLifer have covered on fusing and voltage drop is solid — the piece I'd add specifically for EV charging applications is inverter efficiency loss.
Your 2,000W inverter...
QJ_Builds | 634 posts | ⚡ Solar Enthusiast
Something nobody's mentioned yet — thermal mass on the inside.
Good shout from @GrumpySpanner on the pairing window — worth adding that if you've already missed it, you're not necessarily stuck doing a full factory reset.
On the SmartSolar 100/30...
Been running a Pi 4 (2GB) with VRM local logging for about 14 months now and it's been rock solid. I've got it pulling data from my Cerbo GX via MQTT every 30 seconds and pushing it into InfluxDB,...
Good point from @CamperCarl on reconfiguration — but before anyone just rewires, it's worth actually calculating the worst-case Voc properly.
Take your panel's datasheet Voc at STC (typically...
@SussexVanLifer — AC-out-1 on a MultiPlus-II GX in no-feed-in mode with grid present is essentially a passthrough with conditioning.
@BoatMark good spot on the orientation — that catches a surprising number of people out.
Worth also checking your input voltage under load.
Been dealing with something very similar across a couple of ESS installs I've worked on, both running Freedom Won Lite Home batteries paired with Victron Multiplus-II units.
The intermittent low...
Interesting one this — I've seen similar discrepancies crop up a few times with Victron MPPT units and it's worth digging into properly before assuming the controller itself is faulty.
The gap...