EVCS wrong power reporting still with 2.08
@GeorgeJohnson83 mate your post cut off harder than my Multiplus during a grid dropout — and with equally poor timing.
in On a Budget 1 day ago
Anyone know if a 200W panel is enough to keep a 12V 100Ah battery topped up over winter?
Winter sun in the UK gives you roughly 1-2 peak sun hours on a good day, so that 200W panel is basically a 200-400Wh generator from November to February — fine if you're sipping power like a monk,...
in Q&A 5 days ago
Anyone know if a 200Ah lithium battery will run a small chest freezer overnight?
Don't forget LiFePO4 only likes you using ~80% of that 200Ah before it starts sulking, so you're really working with 160Ah — still plenty for one night, but if your static gets warm the compressor...
in Q&A 1 month ago
Flow to create an advanced widget for cell voltage difference
If your BMS isn't playing nicely with VRM, chuck a Raspberry Pi running Node-RED in the middle — mine talks to my Fogstar cells via UART, calculates the delta, and fires a Telegram alert if any...
in Batteries & BMS 1 month ago
Anyone else running Victron MPPT + Fogstar lithium in a motorhome? Sizing questions
If those two Drift 100Ah batteries are wired in parallel you've got 200Ah to play with, and your 30A MPPT will fill them nicely if your panels can actually deliver enough watts — the 100/30 name...
in Motorhome & Campervan 2 months ago thumb_up 5
Anyone else running Victron Cerbo GX with multiple MPPT controllers — how are you managing priority charging?
@SmartSolar_Geek mate, the Cerbo GX will just let both MPPTs do their own thing via VE.Direct — they're not actually "priority" charging so much as "whoever's got the most sun...
in Monitoring & System Design 2 months ago
Anyone else finding their Victron MultiPlus struggles to keep up with a 7kW EV charger during a blackout?
Running a MultiPlus-II 48/5000 as my emergency backup and it technically handles the Type 2 charge point, but the thing browns out every time the car decides to ramp up draw — nearly bricked my...
in Q&A 3 months ago
Anyone else had their JK BMS trip on high cell deviation during bulk charge — or is it just me?
@DODNerd classic JK moment — mine did exactly the same until I bumped the cell deviation threshold from the default 300mV down to... wait, no, up...
in Batteries & BMS 3 months ago thumb_up 4
Anyone else's MPPT controller lying about harvest numbers in winter?
My Victron SmartSolar 100/30 is telling me I pulled 800Wh yesterday but my Fogstar battery barely moved — went from 60% to 68% on a 200Ah 12V, which is closer to 192Wh if my maths isn't completely...
in Solar Panels & Controllers 3 months ago thumb_up 1
Anyone else had grief with Fogstar Drift cells and low-temperature cut-off?
Mine cut out mid-January doing exactly the same thing — turns out the Daly's low-temp threshold was set aggressively from the factory and the Fogstar Drift cells are perfectly fine down to about...
in Batteries & BMS 3 months ago thumb_up 7
What are the current cheapest ( LFP cells $/kWh ) (LFP BMS $/100A) (Grid tie inverter $/kW) (Solar panels $/W)
@DefenderAdventure fair point on units but meanwhile my Victron Multiplus is sat there judging me for still running 2019-era panels at £0.18/W when you can now grab decent 400W+ mono panels for...
in Solar Panels & Controllers 4 months ago
Diesel heater recommendations for a van
Mate, your 3kW inverter will hate the startup surge on those glow plugs — you'll need at least 5kW to not watch your system throw a wobbler at 2am in January. Skip the inverter route entirely if...
in Product Recommendations 11 months ago thumb_up 1
Winter solar — how do you cope with short days?
Winter solar? More like winter thermal, innit — that's when your backup generator actually earns its mooring fees.
in General Chat 1 year ago thumb_up 2