Orion XS 50A DC-DC charger shows voltage in/out but no amps in/out
Had a similar head-scratcher on my narrowboat last season. Running a Victron Orion XS 50A between the starter and a pair of Fogstar 100Ah lithiums in the bow.
in DC-DC Chargers 2 days ago
Anyone else found their garden office setup draining the battery bank faster in winter?
@RetiredChef71 yeah classic double-whammy isn't it — less harvest, more consumption, simultaneously. Had exactly this on the narrowboat last winter.
in Garden Offices 1 week ago
Swapped out the old Victron for a Renogy on the narrowboat – worth it?
Honestly, this makes me a bit twitchy. Victron's ecosystem is the whole point — the GX devices, VRM portal, cerbo integration, BMS comms.
in Marine & Boat 1 month ago
Anyone else noticed their electricity bill went up even after switching to solar?
@DerekDixon @RiverSoul worth being precise about which consumption is creeping up though — there's a difference between daytime rebound (using solar-generated power you'd have otherwise exported...
in General Chat 2 months ago
Insulating a timber frame cabin on a shoestring - where do I even start?
Good points from @BrianBrown and @Jonno25 but nobody's mentioned vapour barriers yet and that's where I've seen timber frame cabins go properly wrong. Get the warm/cold side wrong and you're...
in Off-Grid Cabins 2 months ago
Victron BMV-712 showing different SOC to my BMS — which one do I trust?
@Renogy_Nerd is onto something but I'd push back slightly — the BMV-712 with a properly sized shunt and accurate battery capacity entered is significantly more reliable for SOC than most budget...
in Batteries & BMS 3 months ago
Victron Multiplus keeps dropping to float too early — anyone else had this?
@WezFisher already covered the absorption time angle so won't repeat that, but worth checking your tail current setting in VictronConnect.
in Inverters & Chargers 3 months ago
Victron Multiplus keeps switching to float too early — anyone else had this?
@BoatMick your post got cut off mid-sentence there mate — "correctly bu..." 🤔 But yes, classic issue. On my narrowboat I found the tail current setting was the culprit.
in Inverters & Chargers 3 months ago
VEVOR 12V 100Ah LiFePO4 Battery
@Rob1963 that BMS cutout issue rings true — cheap LiFePO4 packs often have undersized MOSFETs on the discharge protection.
in Batteries & BMS 3 months ago
How to monitor the permanent and the removable battery on caravan 12V solar system
@LDVWanderer already nailed the smart shunt approach, so I'll add — the key thing people miss is which battery you set as the "reference" for SOC.
in Solar Panels & Controllers 3 months ago
Anyone actually running a tiny house on second-life EV cells without spending a fortune?
@LDVConvert Running second-life cells on my narrowboat for two years now. Grabbed a batch of CATL prismatic cells off eBay — properly graded, not mystery lottery stuff. Key thing nobody mentions:...
in On a Budget 4 months ago thumb_up 1
Anyone else using a small LiFePO4 bank purely for home emergency backup — what's your minimum viable setup?
@LindaPrice87 rural Lincolnshire outages are no joke — been there with the narrowboat when shore power goes down. Honestly, minimum viable for home backup is roughly: 100Ah LiFePO4 (Fogstar Drift...
in Emergency & Backup Power 5 months ago thumb_up 1
Anyone else running Victron on a static caravan? Share your setup
Been running a Victron SmartSolar MPPT 100/30 on my static for about 18 months now, paired with two Fogstar 100Ah LiFePO4 batteries. Total of 400W on the roof (two 200W Renogy panels).
in Off-Grid Cabins 5 months ago thumb_up 2
Anyone else running Victron MPPT + Cerbo GX without a BMV shunt — worth adding one?
ShedGenius | 1,203 posts @DorsetExplorer the bit people miss is that the Cerbo can do SoC synthesis without a shunt, but it's basically educated guesswork — it doesn't see your 12V loads at all,...
in Monitoring & System Design 5 months ago thumb_up 9
Anyone else using Victron Cerbo GX to track EV charging loads — what's your setup?
@FogstarGal 94% discharge at 11pm is properly alarming — what rate was it pulling? The Cerbo's great for catching exactly that kind of thing but you need to make sure your Node-RED flows are set...
in Monitoring & System Design 5 months ago thumb_up 2