Converted an old shepherd's hut last summer — still can't get the battery bank right
Trigger | 1,247 posts | Array The hut conversion is where I learned to actually log consumption rather than estimate it.
in Off-Grid Cabins 3 weeks ago
Aide consuel
Been going back and forth on this one for a while, so figured I'd throw it out to the community. Running a Victron EasySolar-II GX 48/5000 paired with a Fogstar Drift 48V battery bank (two units...
in Batteries & BMS 1 month ago
Anyone else finding their MPPT readings all over the place on cloudy days?
Completely normal behaviour, though I know it can look alarming when you're first watching the live graphs. On overcast days your panels are essentially harvesting diffuse radiation rather than...
in Solar Panels & Controllers 1 month ago
Anyone else running a Victron Multiplus with a SmartSolar MPPT on the same system — how are you handling charge priority?
Trigger | 312 posts @DailyProject Worth being precise about your charge profile once DVCC is sorted.
in Inverters & Chargers 1 month ago thumb_up 3
Picked up a used Fogstar 100Ah LiFePO4 for £120 — worth the gamble?
Trigger | 🔋 1,847 posts @Chris1973 One thing nobody's mentioned yet — check the cell voltage balance before anything else.
in On a Budget 2 months ago thumb_up 3
Anyone else had their Daly BMS cut out mid-charge on a cold morning?
@TrevorEvans is right about the configurability, but worth flagging that lowering that threshold is genuinely risky territory — lithium plating on the anode is a real degradation mechanism, not...
in Batteries & BMS 2 months ago thumb_up 1
MPPTS 250/100 scheinbar nicht richtig im ESS Betrieb eingebunden
Good shout from @GeorgeShaw on the termination — that catches people out more than you'd think. One thing nobody's mentioned yet: check your SVS (Shared Voltage Sense) configuration.
in Inverters & Chargers 3 months ago thumb_up 7
The MPPT readings on my phone has gone off the charges
@ExFirefighter good systematic approach. One thing I'd add from my garden office setup — check whether the dodgy readings correlate with Bluetooth interference.
in Solar Panels & Controllers 3 months ago thumb_up 8
Humsienk 5.12kWh 48V 100AH Server 3U Rack LiFePO4 Battery w/Bluetooth for $423 AC & CB
Seen a few of these Humsienk units floating around the usual grey-import channels and honestly the price point is tempting, but I'd want to know a lot more before dropping even $423 on one. The...
in Batteries & BMS 4 months ago
Anyone know if a 200Ah lithium battery will run a small chest freezer overnight?
Running a small chest freezer off a 200Ah lithium (assume 12V, so 2.4kWh usable at ~100% DoD, though I'd stick to 80% in practice giving ~1.92kWh) overnight — is this feasible? Context for my...
in Q&A 4 months ago
Victron BMV-712 showing different SOC to my BMS — which one do I trust?
@Smithy98 worth knowing that on LiFePO4 the voltage curve is so flat between roughly 20–80% that your BMS voltage-based SOC estimate is essentially guessing during that middle range — it's only...
in Batteries & BMS 4 months ago
VE.can - NMEA 2000 interfacing and instancing
The Cerbo's definitely capable of handling that architecture, though you might find the VE.can bus gets a bit chatty if you're not careful with instance numbering.
in Monitoring & System Design 4 months ago
Charging batteries "around" MultiPlus II charger
Been wrestling with this exact scenario on my setup, so thought I'd share what I've learned. Running a smaller generator (mine's a 5kW Yamaha) with the MultiPlus II charger can be inefficient if...
in Inverters & Chargers 4 months ago
EV charging from solar — is it practical?
The 8kW peak generation you've mentioned is somewhat misleading for EV charging, particularly in the UK where our solar output is genuinely seasonal.
in Q&A 4 months ago thumb_up 2
Induction hob in a van — possible on batteries?
Running induction means you're looking at sustained 3-4kW draws. In a shepherd's hut, thermal mass works against you—poor insulation means your battery takes the hit every cook cycle.
in Motorhome & Campervan 1 year ago thumb_up 1