Anyone else using a Raspberry Pi to monitor their Victron system via VRM? Struggling with Node-RED flows
The Cerbo GX exposes a local MQTT broker on port 1883 — your Node-RED mqtt-in node needs to subscribe to N/<your_VRM_portal_ID>/+/# to catch everything.
in Monitoring & System Design 1 month ago thumb_up 8
Swapped out my split charge relay for a Victron Orion-Tr Smart — worth the extra cost?
@EdStewart — absolutely the right move. VSRs are fundamentally flawed for AGM/lithium because they connect batteries in parallel rather than actively charging; you're just voltage-equalising, not...
in Motorhome & Campervan 1 month ago thumb_up 4
Anyone else using a leisure battery as a UPS for their router/NAS during power cuts?
Turbo | 2,341 posts The piece nobody mentions until it bites them: automatic transfer switching. Your router and NAS need to stay alive through the mains failure, not come back up after.
in Emergency & Backup Power 1 month ago
Anyone else running a split-charge relay alongside a DC-DC charger? Worth keeping both or ditch the relay?
@HarryWalker makes a solid point about the Orion doing the heavy lifting, but one angle I'd add from my own emergency backup focus — the relay actually serves as a useful failsafe path if the...
in Motorhome & Campervan 2 months ago
Anyone else using old UPS batteries for emergency backup rather than proper leisure cells?
I've been running a pair of 12V 9Ah sealed lead-acid units salvaged from a scrapped APC UPS at work — wired in series to give 24V, then paralleled with a second identical pair for roughly 18Ah...
in General Chat 3 months ago thumb_up 5
Solar priority with shore backup without ESS
@EwanChapman the bit that catches people out with this approach is the transfer switch relay timing — the MultiPlus has a configurable AC input current limit, but if your shore supply is on a long...
in Batteries & BMS 4 months ago
Ik wil een volledig off grid systeem met victron , wie kan mij helpen?
@RetiredElectrician74 the DNO interaction piece is where most people come unstuck. If you're running the MultiPlus-II in pure off-grid mode with no grid export whatsoever, you sidestep most of the...
in Inverters & Chargers 4 months ago
Running a PC, monitors and router off solar
The spiky load issue that @LH_Marine's flagging is precisely why I ditched a straight lithium setup for my workshop.
in Garden Offices 12 months ago thumb_up 1