Tigo 240v Split Phase TSI-3.8k-US Grid Tied Inverter- Perfect for Plug-In Solar - New in Box - 152 month warranty - Ships from Oregon
@Pylontech_Wizard to finish that thought — getting it certified under G98/G99 for grid-tie in the UK would be a complete non-starter.
in Inverters & Chargers 1 week ago
The Harley Bike Battery and BMS
@IvyLes worth distinguishing which Harley batteries you're looking at. The OEM Yuasa/Deka AGMs are decent build quality but rated for shallow cycling — primarily cranking batteries, so expect...
in Batteries & BMS 1 month ago
Swapped out the old Victron BMV on the narrowboat – worth it or overkill?
Depends entirely on what you swapped to, doesn't it? If you've gone from a BMV-712 to the SmartShunt + GX device combo, that's a genuine upgrade — proper system integration rather than just a...
in Marine & Boat 1 month ago
Victron MPPT keeps dropping out on cloudy days — is this normal?
@RussHunt82 the "existential crisis" description is pretty accurate tbh. Worth checking your absorption voltage threshold — if it's set too high for your battery chemistry, the MPPT will...
in Solar Panels & Controllers 1 month ago
Narrowboat inverter keeps tripping on the washing machine – 12v or 24v system worth upgrading?
Been through exactly this with a static setup but the principle is the same — washing machines are notorious for their startup surge.
in Marine & Boat 2 months ago
Anyone else running Victron Multiplus as their main inverter/charger in a van build?
Fitted a Multiplus-II 12/3000 in my Transit last spring alongside a 200Ah Fogstar Drift LiFePO4 and a 400W Victron MPPT setup.
in Motorhome & Campervan 5 months ago thumb_up 2
Anyone else finding cheap MPPT controllers lying about their charging voltages?
@RetiredElectrician10 worth grabbing a decent calibrated multimeter and measuring directly at the battery terminals during bulk/absorption transitions — not at the controller's display.
in Q&A 5 months ago thumb_up 7
Anyone else had grief with a Victron MultiPlus 12/3000 cutting out under heavy load?
BatteryDaz | Posts: 1,203 | Location: Array Worth checking your VEConfigure settings — specifically the Low battery shutdown and Dynamic current limiter options.
in Inverters & Chargers 5 months ago thumb_up 7
Anyone else had issues with a JK BMS cutting out under load with LiFePO4 cells?
@NickMason First thing I'd check is your cell-level voltages under load — if one cell is sagging significantly more than the others, the JK will trigger an undervoltage cutout even if the overall...
in Batteries & BMS 5 months ago thumb_up 4
Anyone else finding their Fogstar Drift cells are absolutely spoilt rotten compared to cheaper alternatives?
@SolarDoug one thing I'd add for a cabin build — I've got 8x280Ah Drifts paired with a Victron SmartSolar and Multiplus-II, and the inter-cell variance after six months of cycling is genuinely...
in Batteries & BMS 6 months ago thumb_up 6