@RetiredEngineer nailed it. 125A is brutal for a single battery's BMS.
Few things worth checking:
Cable gauge — undersized cables will drop voltage enough to trigger low-voltage cutoff before the...
Seen a few of these pop up on eBay and Amazon lately. The price point is tempting, no question — but I'd want to know a lot more before putting one anywhere near my setup.
A few things I'd be...
Been through similar on my boat up around the west coast — Scottish summers look great on paper but the solar yield is genuinely poor for days at a stretch.
Few things that made a difference for...
Both posts cut off mid-sentence which is doing my head in 😄
@MarkAllen69 if you can finish your thought that'd help, but guessing you mean the AC input/output figures weren't displaying?
Had this exact headache on my boat build last year. Short answer: trust neither blindly, use both.
The SmartShunt is only as good as its calibration — if your charged voltage threshold or tail...
Had a similar head-scratcher with my SmartShunt a while back — the starter battery voltage was reading completely off compared to what my multimeter was showing at the terminals.
Turned out the...
@BatteryPaula solid setup choice. One thing I'd add that catches people out — fuse as close to the positive terminal as possible on each battery. Not at the load end, not halfway along the cable.
Picked up a 200Ah Fogstar Drift last spring and it's been brilliant all summer. Now temps are dropping I'm getting the low-temp cutoff kicking in around 4–5°C, usually early morning before the...
@Finn1991 makes a solid point on SOC thresholds. I'd add — watch your charge rate vs panel input ratio carefully.
in Q&A
2 months ago
thumb_up 8
Good shout from everyone here. One thing I'd add — check the input voltage threshold in the Victron Connect app.
@RiverFinn same pattern on my boat build — Renogy would lose track completely then take ages to re-sweep and find the MPP again after cloud cover.
@DucatoSolar yes, similar setup here on my narrowboat. Pi 4 (4GB) pulling data from a Victron SmartShunt and MPPT via VE.Direct.
@Ollie1981 and @EdGrant91 have covered voltage sensing well so I'll add something different — check your tail current setting.
SmartShunt's integration with Victron's ecosystem is the real win for me. Paired with a MultiPlus, it's seamless—the shunt resistance thing sorted itself once I calibrated against known loads.
Nice one, @OldSparky. The portability angle is what makes these boxes actually useful — beats lugging a full battery bank around.
Curious about your wiring setup though.