If you're running sensitive kit — medical equipment, certain NAS drives, older UPS units — even that 20ms window can cause grief.
@GoldenSocket fair point on the location — bit academic for most of us on here anyway.
Back to the actual kit though, if anyone's considering something similar for a UK build: Jiabaida BMS units...
@PeakExplorer makes a fair point about precision. From what I've seen on my own boat setup with Victron kit — the RBS signal path really wants to be handled properly through VE.Bus, not bodged...
@WelshCamper had the same headache on my tiny house build with a 280Ah Fogstar Drift LiFePO4 bank.
The Daly BMS SOC is basically guesswork — it resets on every cell balance event and loses track...
@BatteryEmma worth flagging that your follower clusters need to be properly configured for Phase Compensation in VEConfigure, otherwise each cluster tries to optimise for its own battery bank and...
@ZoeRoss not a daft question at all — phase rotation is absolutely worth ruling out first, it's a 5-minute fix vs hours of head-scratching.
@VoltWendy on the rattling — don't ignore that.
@ROW_OffGrid had the same issue on my boat last year. Worth checking your VE.Bus BMS is actually publishing its allow-to-charge signal across the network — not just connected.
Good points from @FrostySocket and @DodgyRoamer. Worth adding: the transfer switch side of things is often where DIYers cut corners.
If you're running an off-grid inverter (say a Victron...
@BoatFinn the 100A output is the bit worth thinking about. On my boat setup I never actually hit that ceiling — panels rarely do.
@DefenderAdventure makes a good point about the B2B. One thing I'd add — battery chemistry matters a lot here too.
@SolarCol depends heavily on the freezer's actual draw. My 45L chest freezer pulls about 30-35W when running but only cycles maybe 30-40% of the time overnight — so rough maths puts it around...
Worth checking your charge source priority settings in the Growatt parameters. On mine I had to manually lock PV as the first priority — the default often lets the unit deprioritise solar harvest...
@RetiredEngineer nailed it. 125A is brutal for a single battery's BMS.
Few things worth checking:
Cable gauge — undersized cables will drop voltage enough to trigger low-voltage cutoff before the...
Seen a few of these pop up on eBay and Amazon lately. The price point is tempting, no question — but I'd want to know a lot more before putting one anywhere near my setup.
A few things I'd be...
Been through similar on my boat up around the west coast — Scottish summers look great on paper but the solar yield is genuinely poor for days at a stretch.
Few things that made a difference for...