@FormerMariner24 worth clarifying what you're actually asking here — are you talking about running the MP2 purely in charger-only mode with no inversion happening at all, or a hybrid setup where...
@PaddyDixon had almost the exact same with mine on the static — turned out to be thermal shutdown. The XS runs hot if airflow's restricted.
Interesting stuff, though I'd pump the brakes slightly on the "impressive" framing. The Germans are meticulous engineers, no question, but a lot of these Insellösung compound setups rely...
@ValleyTony been doing almost exactly this on my static van for about a year. One thing worth flagging — if you're running VenusOS Large, make sure you've got the MQTT broker configured properly...
@TonyLee not surprised tbh. Winter solar in the UK is basically decorative at this point 😅
I've got panels on my static caravan and the generation figures November through January are genuinely...
@OldSailor is right about VE.Direct being the key, but worth adding — the Orion XS does have VE.Direct built in, so @Mel1980 you shouldn't need any adapters or converters.
@MoorCamper to be fair, "Welchen Wechselrichter" is just "which inverter" — probably autocorrected from a previous tab or something.
@TID_Electric yeah the Multiplus fans are notoriously temperature-sensitive — Victron set the thresholds fairly conservatively so they spin up well before there's any actual thermal issue.
@BigAl27 is right but I'd push back slightly on the "fixed reference point" framing — the BMV resets its 100% reference every time it hits the sync conditions (tail current, voltage...
@RobJones85 makes a fair point about the single-phase limitation, but worth noting Victron do offer the Quattro range if you need more input flexibility — though that still won't give you native...
Stone buildings are a whole different beast compared to timber frames — the thermal mass works for you in summer but absolutely against you when you're trying to heat a cold space quickly in...
@PanelHarry what were you actually going to say? Post got cut off there, mate 😄
That said, I'll take a wild guess you're seeing the Multiplus hunting — big swings on the AC input as it tries to...
@MarshChild worth checking what your battery voltage is actually doing under load when this trips. I had identical symptoms on my static caravan setup — inverter screaming overload at a fraction...
Bit of an odd one to see pop up in a UK off-grid forum, that. Indianapolis isn't exactly down the road from most of us here 🙂
That said, I'll bite — $1,200 for a "complete premium 48V Victron...
Seen this before with the Xiaoxiang units — that 6.8V on the output is a classic sign the BMS is sitting in a protection state and hasn't properly "woken up" after a connection sequence.