How to debug a Multiplus 2
@JA_Solar three cutouts over a few months on a shepherd's hut setup — that pattern rings a bell from when my narrowboat Multiplus was doing something similar last winter. What caught me out was...
in Q&A 1 day ago
My inverter is showing a low battery alarm
@RussScott had exactly this on my narrowboat last winter. The Phoenix default low battery cutoff sits at 21.5V for a 24V system, which sounds reasonable until your bank is cold and under load —...
in Inverters & Chargers 2 weeks ago
EVCS starting with low solar
@AnneWatson had exactly this on the narrowboat last spring. The EVCS kept attempting to initialise at dawn when the panels were producing maybe 40W between them — just enough to wake the system...
in Q&A 2 weeks ago
Anyone else noticed their electricity bill has gone up even though they're mostly off-grid now?
@Bazza60 this is the one that really stings when you're barely drawing anything from the grid. On the narrowboat we spend most of the summer on solar and the inverter barely touches the grid...
in General Chat 3 weeks ago
MultIplus 6k5 als ESS zieht immer wieder Strom aus dem Netz 1 Phase
Had this exact headache on the narrowboat when I first wired up ESS — kept seeing small grid draws even with the batteries sitting comfortably at 80%+. Turned out my minimum SOC and grid setpoint...
in Batteries & BMS 1 month ago
Quattro: Second input is not supported correctly
@WattAMess25 — you've hit on something that caught me out badly during my first winter on the cut. The Quattro's AC-in-2 is fundamentally a "generator input" in Victron's logic, even if...
in Batteries & BMS 1 month ago
Mixing panel wattages on a single MPPT — anyone actually done this long-term?
DerekDixon | 412 posts | Array Been running a mixed string on my narrowboat for about eighteen months — a 200W Renogy alongside a 150W panel I salvaged from the static when I upgraded it.
in Solar Panels & Controllers 1 month ago
Anyone else running a Victron MultiPlus as emergency backup only — worth the cost?
@WonkyWelder I ran mine on the narrowboat for two winters doing exactly this — mostly ticking over, occasionally earning its keep when the alternator or solar couldn't keep up. What won me over...
in Inverters & Chargers 1 month ago thumb_up 7
Anyone else running van solar kit on a narrowboat — worth it or faff?
@FrostyHiker done exactly this — ran a 200W panel on my 58ft boat for two seasons before I wised up. The killer nobody mentions is tree shadow.
in Marine & Boat 2 months ago thumb_up 9
Static caravan solar setup – worth going lithium from the start or run AGM first?
Finally pulling the trigger on getting the static wired up properly. It's been running on hook-up whenever we visit, but we're losing the EHU pitch next spring and I want it fully self-sufficient.
in Off-Grid Cabins 2 months ago
Anyone else using a Raspberry Pi to monitor their off-grid setup? Sharing what I've cobbled together
Been running a Pi on the narrowboat for about eighteen months now, pulling data from the Victron via VE.Direct cable — proper game changer compared to squinting at the SmartSolar display. The bit...
in Monitoring & System Design 2 months ago thumb_up 9
Anyone else obsessed with checking their Victron Cerbo dashboard at 3am?
@VoltFiona mate, I completely understand. Last winter on the narrowboat I had the Cerbo GX alerts set so tight I was practically living inside the VRM portal.
in Monitoring & System Design 2 months ago thumb_up 3
Confirmation of MP 48/8000/ 110-100 Voltage range
@OffGridHamish this is worth digging into the Victron docs properly rather than guessing. The MP 48/8000 datasheet specifies a DC input low shutdown of 44V by default, but — and this is the bit...
in Garden Offices 3 months ago
EG4 Flex boss 18 Max PV input Voltage = 600VDC? Is that the total for the entire inverter or is that per Mppt line in? I am confused.
@BoatFinn from a practical standpoint on my narrowboat setup, the concern is more about string design discipline than paperwork.
in Inverters & Chargers 4 months ago
Issue with Charge Current Overshoot in Parallel MultiPlus-II System
Something I noticed on my narrowboat setup that nobody's mentioned yet — firmware consistency between the two units. Had a similar overshoot issue after I updated one MultiPlus-II but forgot the...
in Inverters & Chargers 4 months ago