Anyone else had grief with Victron Multiplus fan running constantly even at low load?
Picked up a secondhand Multiplus 12/3000/120 a few months back and it's been brilliant overall, but the fan never seems to shut off — even when I'm barely pulling 200W through it.
in Inverters & Chargers 3 days ago thumb_up 5
Anyone else running a Victron Orion-Tr Smart in absorption without a proper alternator health check first?
Good points all round. One thing I'd add — don't overlook the age and condition of your drive belt while you're at it.
in DC-DC Chargers 5 days ago thumb_up 5
Anyone else finding narrowboat solar frustrating in winter?
DuctTapeDave60 | 847 posts | ⚓ Afloat somewhere near Braunston @BirchTrevor Totally feel your pain mate.
in General Chat 1 week ago thumb_up 6
Victron MultiPlus-II 48/3000 keeps dropping to float too early — anyone else seen this?
Reply by DuctTapeDave60: @FETGeek had almost identical bother with my Pylontech setup a while back. Worth checking your tail current threshold in VEConfigure — if it's set too high, the MultiPlus...
in Inverters & Chargers 1 week ago thumb_up 9
Swapped out my 100Ah AGM for a 100Ah LiFePO4 — same capacity but it feels like a completely different setup
Been running a fairly standard 12V setup in my Transit-based van for the past three years — 100Ah AGM, 200W of solar on the roof, and a Victron MPPT 75/15 controller.
in Motorhome & Campervan 2 weeks ago thumb_up 1
Anyone else running a Renogy MPPT alongside a Victron unit on the same bank?
@FormerMechanic15 Worth keeping an eye on how the two controllers negotiate charging — in my experience the Renogy will tend to back off once the Victron has pushed the bank to absorption, but...
in Solar Panels & Controllers 3 weeks ago thumb_up 2
Anyone else gone the Fogstar Drift route for a budget cabin build?
DuctTapeDave60 | 312 posts Good shout @Rodney. I went twin 100Ah Drifts in parallel rather than a single 200Ah — gave me flexibility to add a third later without replacing the whole bank.
in On a Budget 3 weeks ago thumb_up 5
Anyone else had grief with MPPT controllers draining batteries overnight?
DuctTapeDave60 | Posts: 2,156 | Location: Yorkshire Dales @HeatherOllie worth checking your battery temp sensor if you've got one fitted.
in Solar Panels & Controllers 1 month ago thumb_up 8
Anyone else using a Victron Cerbo GX with non-Victron inverters? How are you handling the monitoring gap?
DuctTapeDave60 | Posts: 1,203 @PartnerConvert I've been running a similar mixed bag on my off-grid barn conversion for a couple of years now.
in Monitoring & System Design 1 month ago thumb_up 5
Anyone else running a split-charge relay off a leisure battery bank on the cheap?
Been faffing about with my setup this week and thought I'd share where I've got to. I've got two 100Ah AGM batteries wired in parallel (picked up secondhand off Facebook Marketplace for £40 the...
in On a Budget 2 months ago thumb_up 3