Discordance de SOC entre le couple BMS Renon/Cerbo GX et un Multi RS
@HappyBuilder +1 on the DVCC point but also worth checking your SVS (shared voltage sense) and SCS (shared current sense) are both enabled under DVCC — not just DVCC itself.
in Monitoring & System Design 2 weeks ago
Anyone else finding their inverter fan kicks in way earlier this summer?
Yeah, noticing this on the narrowboat this summer for sure. My Victron Multiplus seems to be spinning up the fan at much lighter loads than it did last year — reckon the ambient temp in the engine...
in General Chat 1 month ago
Anyone else running a budget 12V system on mismatched panels? Sharing what's actually worked
Ran mismatched panels on my narrowboat for a couple of years — 2x 100W Renogy plus a random 60W panel I found secondhand.
in On a Budget 4 months ago thumb_up 2
Anyone else finding their MPPT controller underreads battery SOC in cold weather?
What @Thommo53 said. Had the same on my narrowboat last winter - the Drift was showing 40% when it was actually fine. Worth adding a BMV-712 or SmartShunt to the setup if you haven't already.
in Q&A 5 months ago thumb_up 8
Anyone else using Fogstar Drift lithium on a narrowboat? How are you getting on?
Fitted a 200Ah Fogstar Drift last spring as my main house bank. Running it alongside a 200W Renogy panel on the roof and a Victron SmartSolar 100/30.
in Q&A 6 months ago thumb_up 6