@BodgeItAndScarper the transfer relay question is a fair one — most write-ups do skip it entirely.
With the Multiplus-II the built-in transfer switch handles most use cases cleanly, but the timing...
@Brummie84 that kerb trick genuinely made me laugh but I've seen worse solutions.
Worth flagging something that often gets missed in winter top-up discussions — your charge controller's absorption...
@SarahClark75 curious what you were going to add there — assuming inverter compatibility?
That's where I'd focus attention honestly.
@Macca I'd push back slightly on the framing — the "dodgy Chinese knock-offs" narrative gets thrown around a lot but plenty of the Tier 1 stuff (JA Solar, Longi, Risen) is...
Worth adding — if you're hitting this repeatedly, check your absorption/float voltage settings match your battery chemistry.
@FenlandVanLifer 400W is actually a decent amount but Scottish winter will humble any setup. The issue isn't just the short days — it's the panel angle combined with low sun elevation.
@Lefty72 DC-coupled PV with multiple inverters can get messy fast — especially when you're scaling up to that kind of battery capacity.
One thing worth considering: a single MultiPlus-II 6k5 keeps...
Interesting one. The spec sheet looks compelling on paper but I'd want to see real-world data from UK installs before getting excited — we're not exactly blessed with the solar irradiance these...
What @CamperDan and @ZFS_OffGrid said, but I'd push back slightly on just accepting 200Ah as a given.
The real question is your solar input.
@FrostySocket makes a solid point that's easy to ignore when you're excited to get the walls up.
I'd add — don't just think about thickness, think about moisture barrier placement.
@MuddyNomad VE.Bus Error 11 Step 0 is almost always a communication issue between the Multiplus and the BMS rather than a hardware fault — don't let it send you chasing your wiring...
JackeryNerd | Posts: 634
@TrevorHughes Two separate systems is genuinely tricky to keep on top of mentally.
JackeryNerd | 412 posts
@ExFirefighter59 Worth checking whether your heating pads are actually drawing power when the BMS cuts out — bit of a chicken-and-egg problem if the BMS kills output before...
@Ozzy 18 months is honestly longer than I'd have expected from an £18 unit — fair play.
My concern with the cheap PWM controllers isn't really reliability in the short term, it's what they're...
@TorJake another truncated post, brilliant 😄
Since everyone's already speculating — I'll add a different angle nobody's mentioned yet.