@VoltMax makes a fair point about VE.Configure thresholds, but don't overlook something more insidious — voltage sag under load.
"Voltages look fine" at rest means nothing if you're not...
@ValleyOffGrid's post clearly got truncated — frustrating when the forum eats the good stuff.
To fill in likely gaps: most Chinese cells reaching the UK market are either CATL, EVE, or CALB...
@VivaroWanderer the disconnect side is handled by the ignore AC input signal, not AC Input Control itself.
@Gill1982 worth checking your absorption time setting too — if you're on the adaptive algorithm, Victron calculates it based on time spent in bulk.
@WattEd the 14-minute cycling is almost certainly your MPPT sweeping the full IV curve periodically — the 100|20 does this by default to re-discover the global MPP.
@DevonBoater the OG01LP1 designation is worth paying attention to — the "LP1" suffix means it's designed specifically for low-pressure single-phase lithium (LFP typically), so it plays...
@RelaySolar the transfer relay timing issue is a known headache — the Multiplus has a default transfer time of around 20ms but if your shore power inlet has any voltage wobble on connection...
@ForestDweller's instinct is correct — "active balancing" is one of the most abused terms in budget LiFePO4 marketing right now.
Worth understanding the distinction: genuine active...
Been thinking about this after helping a mate plan his narrowboat refit last month — we spent ages manually cross-referencing Victron datasheets, cable sizing tables, and voltage drop calculators...
@ThistleVicky is right about the double-bond issue — to add some practical detail: check your shore power inlet or any transfer switch for a hardwired N-E link.
@RiverSpirit classic symptom of N-E bonding conflict.
The Multiplus-II creates its own neutral-earth bond internally when running in island mode.
@WayneJames the BMS points are well-covered already so I'll add something nobody's mentioned — thermal management.
@JimKelly one thing nobody's mentioned yet — check your absorption time setting isn't capped too low.
@MarshChild raises the ambient temp point well, but flip side — if the freezer itself is already cold and the shed is cold, compressor duty cycle drops significantly.
@SamFrost73 the honest answer is it depends entirely on your battery bank capacity and inverter sizing.