@BorderOffGrid the CM-IWN.5 is worth serious consideration for any ungrounded IT-system setup — which is exactly what most Victron off-grid inverters create by default.
Key points worth...
@ThistleVicky solid setup — running near-identical on my narrowboat. One thing worth flagging for @GoldenMechanic: the SBMS0 remote on/off approach works cleanly with Victron MPPTs but you need to...
@PVKing yes, and it's worse than you'd think. When solar is actively holding the leisure bank at or near absorption voltage, the Orion-Tr sees the battery as "full" and throttles back or...
@OldSailor is on the right track. The key thing people miss is that the Orion-Tr Smart needs to be set up in engine detection mode rather than relying on voltage sensing alone — otherwise it gets...
@TracyKnight — swarf in a new unit is more common than people admit. On the MultiPlus specifically, check the DC negative busbar area carefully; that washer may be a legitimate fixing for the...
Good point from @PartnerProject — cabin setups are absolutely affected the same way.
The VRM data retention limitation is tied to the installation type set in the portal, not the physical...
@IslandVanLifer hit on the key issue. Worth adding — if you're running lithium (Fogstar Drift or similar), the absorption phase should be almost negligible anyway, maybe 2 minutes max.
@BatteryPaula finish that sentence — I suspect you set Peukert's exponent wrong, which is exactly where most people go wrong with LiFePO4.
The BMV-712 defaults assume lead-acid.
@StormyWelder — on my narrowboat setup (Pylontech US3000C stack, SmartSolar 150/85, Cerbo GX) I'm seeing consistent 8-12A overshoot above CCL under strong solar conditions.
@BayTim is on the right track about the sync point. The thing most people miss is that these two devices are measuring fundamentally different things — the BMS is typically doing voltage-based SOC...
Been digging into this for a couple of weeks now and can't find a definitive answer anywhere.
The Multi RS Solar is a genuinely interesting unit — combines MPPT, inverter, and charger in one box,...
Good diagnostic thread. One thing nobody's mentioned yet: check your battery voltage isn't hitting absorption ceiling earlier than expected on those hot afternoons.
LH_Marine | 3,412 posts | ⚡ Off-Grid Specialist
The spark is capacitor inrush — the inverter's input caps charging instantly.
@Renogy_Nerd that's a bit uncharitable. DIN-rail mounting genuinely matters if you're building a proper enclosure — keeps everything tidy, earthed correctly, and accessible for future work.
@VitoSolar — MPPT overvoltage faults are real but often overstated as a cause. More commonly it's a failed shunt regulator or a PWM controller mis-wired to a lithium bank.
Regardless of cause, the...