Variable peak shaving and Dynamic ESS
Been through this exact faff with my own Multiplus-II setup. One thing worth checking that nobody's mentioned — if you're running Dynamic ESS via VRM, make sure your BatteryLife setting isn't...
in Q&A 5 days ago
Victron lfp internal balance start voltage per cell?
Been thinking about this a lot lately after pulling apart an old battery bank and reusing the cells in a new setup. Got a few of the older Victron LFP packs — the ones with the 3-pin comms lead...
in Batteries & BMS 1 week ago
Orion xs settings AGM
@KeithMurray worth checking whether your AGM has a gel-style profile option in the Orion XS — some manufacturers spec their sealed AGMs closer to 14.1–14.2V absorption rather than the full 14.4V.
in DC-DC Chargers 2 weeks ago
Mppt100/30 troubleshooting
Been scratching my head with my MPPT 100/30 for the past couple of days and wondering if anyone's had similar. I've got a pair of 200W panels wired in series giving me around 72V open circuit,...
in Q&A 3 weeks ago
Getting the Smartshunt AUX to work
Been meaning to post about this for a while — finally getting round to it after a frustrating weekend. I've got a Victron SmartShunt on my main LiFePO4 bank (Fogstar Drift 200Ah if anyone's...
in Monitoring & System Design 3 weeks ago
Compliant California Critical loads panel inverter/battery systems
Interesting topic - slightly outside my usual UK stomping ground but the principles are universal enough to be worth chipping in. The "critical loads" panel concept is something I wish...
in Inverters & Chargers 2 months ago
Quattro: Second input is not supported correctly
@MarineGeoff has nailed the core issue — passthrough only is the key thing people miss. Worth adding though: if your shore power on AC-in-2 drops out even briefly, the Quattro won't seamlessly...
in Batteries & BMS 4 months ago
Anyone else had issues pairing a Victron SmartSolar with cheap Chinese panels — odd voltage readings?
@Deano13 worth checking your actual open-circuit voltage before assuming it's a pairing issue. Two panels in series at cold temps can spike well above their nominal Voc — I've seen cheap 200W...
in Solar Panels & Controllers 5 months ago thumb_up 1
Worth running a small 12v system alongside a 48v setup for low-draw overnight loads?
Been running a 48v Victron system for a couple of years now — 4x 200Ah Fogstar Drift LiFePO4s, Multiplus-II, the usual.
in Q&A 5 months ago
Does my battery capacity actually matter if my solar can't keep up on cloudy days?
@NotAnElectrician the missing piece nobody's mentioned yet is days of autonomy — how many cloudy days can you survive without any meaningful solar input? Your 200Ah Fogstar is decent but if you're...
in Q&A 5 months ago thumb_up 9
Victron multiplus2 and dyness power box 10 kwh
Good points from everyone above. One thing worth adding — have you checked your DC bus bar torque settings?
in Inverters & Chargers 7 months ago
Fogstar Drift vs others — 2025 battery showdown
Got a Drift 5.12 myself paired with a 4kW array and honestly the longevity talk from @HighlandExplorer resonates.
in Product Recommendations 7 months ago thumb_up 1