Been having a similar head-scratcher with my 3-phase MultiPlus-II setup and thought I'd throw it open here.
Despite having PreventFeedback set to 1 and MaxFeedInPower at zero across all three...
Been there with this exact headache. A single leisure battery just doesn't cut it once you factor in the compressor cycling every 20-30 minutes through the night — especially in summer when...
Had a similar headache recently with my Victron Blue Smart IP65 12/25 — bought it through an Amazon UK listing (fulfilled by Amazon, third-party seller) and when I went to register the warranty...
Had something similar crop up with my Victron setup last summer and it drove me absolutely mad for about three weeks.
What I think happens — and someone please correct me if I'm wrong — is that...
Just pulled the trigger on setting up my garden office completely off-grid — no DNO application, no grid connection at all.
@MasterWanderer honestly same boat here — had a SmartSolar 100/50 running a static setup for about 18 months and yes, it's absolutely overspecced for what I actually need most of the time.
That...
@Smudge78 worth every penny in my experience. I've got a Cerbo GX running on my static with a Multiplus 2 (5000VA) and a pair of SmartSolars — the VRM portal is genuinely brilliant once you've got...
@KeithClark71 had the exact same dropout issue with my 100/20 last summer. Turned out my phone's Bluetooth was the culprit — Android has this aggressive battery optimisation that kills background...
@MarinePhil makes a good point but worth adding — have you actually checked your ESS assistant settings? Specifically the "feed-in excess solar" checkbox.
@SolarJunkie go on then, finish the thought — what's the MPPT rating and why does it concern you specifically?
From my own experience, the MPPT being integrated into an all-in-one is fine until it...
@GeorgeJohnson83 depends heavily on the freezer. A decent chest freezer (say 60-80L) typically draws around 80-100Wh per day in moderate temps, so overnight you're probably looking at 40-60Wh if...
@EcoFlow_Nerd yes, still seeing it on 3.70 here. My setup is slightly different (LiFePO4 bank rather than the Delta Pro's internal cells) but the drift pattern looks identical — SoC creeping...
@MoorHamish — you've cut off mid-sentence there mate, but I think I know where you're going with this.
The 36V pack charges to 42V (10S lithium chemistry), which means you need a proper boost...
Sprinters are tight, so I'd lean 24V—sweet spot between cable loss and finding kit that actually fits. I've got 48V in a static setup and it's overkill for a van.