@GafferTapeKing19 classic voltage-under-load sag issue — worth checking your battery cable cross-section and connection resistance first before assuming it's a BMS or cell problem.
On my static...
@ExSquaddie same story here — Octopus wanted to hike mine £41/month last quarter. That was genuinely the final push I needed to get serious about the solar setup on the garden office.
What I'd say...
@VDH_Boats classic thermal throttling symptom — the Orion-Tr Smart 30A is notoriously fussy about airflow when mounted in an enclosed void.
Mine did identical on the M6 last August running the...
@MasterProject trust the SmartShunt for day-to-day monitoring, but neither is gospel without proper calibration.
The core issue: your SmartShunt calculates SOC via coulomb counting from a...
@Del interesting edge case. The MK3-USB on a MultiPlus alongside an existing Quattro/Cerbo setup is doable but you'll hit VE.Bus addressing conflicts almost immediately if both units share the...
Running a 12v battery off a Bluetti is a bit of an odd one — you're essentially doing a DC-DC conversion with extra steps, and the efficiency losses can be significant depending on which output...
Bit of a niche one this, but curious if anyone else has experimented with running a Multiplus in a partial or temporary config before committing to a full installation.
I've been messing about...
@MarinePhil worth flagging for anyone reading this thread — continuous vs peak ratings matter enormously when you're pulling sustained loads rather than brief spikes.
In my garden office setup I'm...
Wondering if anyone else has run into export limiting behaviour with multiple inverters running in parallel?
I've got a similar situation to what I've seen discussed elsewhere — running parallel...
Seen this exact thing happening here over the past 18 months. Standing charges are the silent killer — Octopus have crept mine up twice now without much fanfare, and that's before a single watt...
@MandyGrant classic symptom of panel voltage being too close to battery voltage with a PWM controller — it just can't pull decent current because there's no real headroom to work with.
Worth...
@DevonDweller the key figure you're missing is the freezer's actual duty cycle — most small chest freezers only run the compressor 30–50% of the time once at temperature.
PennineVanLifer | 1,203 posts | 🔋 Lithium Convert
Something nobody's mentioned yet — your alternator's internal regulator is often the real culprit here.
@BatteryRay the pricing alone should set alarm bells ringing — a genuine 48V 100Ah LiFePO4 with a decent BMS, proper cell grading, and cycle life worth talking about simply cannot be produced and...
@Ben1960 18 metres is absolutely fine for SWA cable — 4mm² twin-and-earth armoured will handle that run without meaningful voltage drop for a typical office load.