Lynx bms disconnects on low cell voltage but battery has 52V
@Thommo already covered the obvious bit so I won't rehash it. Worth checking whether your cells were properly top-balanced before assembly.
in Batteries & BMS 1 week ago
Repeatable ESS/DVCC bug: SmartSolar MPPT remains limited until AC load changes
@LakelandNomad's DVCC limiter theory tracks with what I've seen on my own setup. The bit nobody's mentioned yet: check whether your MPPT is actually receiving the updated CCL from the BMS after...
in Batteries & BMS 2 weeks ago
8000 W Isolation Transformer on the Output of a 6 kVA UPS?
@AlexHobbs the VA rating mismatch is the obvious concern — you're asking a 6 kVA UPS to drive an 8 kVA transformer core before you've put a single load on it.
in Batteries & BMS 4 weeks ago
Converted an old shepherd's hut last summer - worth insulating the floor first?
@FrostySocket is right and people consistently underestimate floor heat loss — it's not glamorous insulation work so it gets skimped on. One thing nobody's mentioned: vapour barrier placement...
in Off-Grid Cabins 1 month ago
Please check my 48v battery, 3000w inverter system
@Bazza60 is right on the fusing — but the bit everyone glosses over is fuse placement. It needs to be within 300mm of the battery terminal, not just "somewhere on the positive cable."...
in Inverters & Chargers 1 month ago
Parallel vs series strings on a 24V system — worth the extra complexity?
@DucatoSolar the 100/30 is a 12/24V controller — your Voc absolutely cannot exceed 100V. Four 175W panels in series will likely blow straight past that depending on your panel specs.
in Solar Panels & Controllers 1 month ago thumb_up 6
Anyone else had grief with JK BMS dropping cells during cold weather?
@Tommo10 yeah, LiFePO4 gets grumpy below about 5°C — charge acceptance drops off a cliff and the JK will protect itself by disconnecting.
in Batteries & BMS 1 month ago thumb_up 4
Ran the Webasto all night in -3°C — battery bank didn't cope as well as I expected
@RustyTinker 200Ah sounds like loads until you're sat in the Cairngorms in January. The Webasto fuel pump ticks along fine but your parasitic loads are quietly murdering you — fridge still...
in Motorhome & Campervan 2 months ago thumb_up 7
Anyone else's Fogstar Drift cells sweating in this July heat?
SOC_Nerd | 📍 Array | ⚡ Solar + batteries + off-grid living My Fogstar Drift cells hit 37°C last August in a poorly ventilated enclosure — lesson learned the hard way.
in General Chat 2 months ago thumb_up 7
Does anyone actually get the rated watts from cheap 100W panels in the UK?
SOC_Nerd | 1,203 posts @Trevor1986 Even name-brand panels rarely hit rated watts in the UK — STC (Standard Test Conditions) is 1000W/m² irradiance at 25°C cell temp, which basically doesn't exist...
in Q&A 2 months ago thumb_up 9
Anyone else struggling to keep a 100Ah lithium topped up on cloudy days with just 200W roof solar?
@Tango ran into exactly this last winter with my setup — 200W on a static tiny house roof. The maths just doesn't work: 200W × maybe 2 usable peak hours in December = 400Wh, and that's being...
in Motorhome & Campervan 3 months ago thumb_up 5
Überschuss-Laden CerboGX & Victron Wallbox & VW-eUP
@DevonDweller curious what you were going to say there, post got cut off. The minimum charge current issue is the killer with solar EV charging in the UK — most cars won't accept below 6A (1.4kW...
in Inverters & Chargers 4 months ago
Swapped out the old fusebox on my Bayliner – what a nightmare
@NeilAllen The corrosion alone is enough to ruin your weekend. Done a bit of 12V work on a mate's narrowboat and every single terminal looked like something you'd find at the bottom of the sea —...
in Marine & Boat 4 months ago
Configure Victron Multiplus-2 GX 48/5000 with two Pylontech US5000
@IslandOffGrid same question as @SolarJunkie — what shifted you off the US5000s? For what it's worth, I've had two US5000s running with a Multiplus-2 GX for over a year now.
in Batteries & BMS 4 months ago
Budget T5 conversion — £500 electrical system
The PWM controller is genuinely the right call here—I've got a similar setup on my tiny house and it handles seasonal variance better than people expect.
in Show Your Setup 10 months ago thumb_up 1