Never heard of Neovolta before this thread. For a garden office setup I'd probably stick with something like a Victron Multiplus paired with a Fogstar battery — more local support if something...
Yeah both valid points tbh. The thing I'd add — calibration matters massively with the BMV-712. If your battery capacity figure is slightly off (and it usually is with Fogstar Drift cells that...
Had this exact same gremlin with my garden office setup last year. Turned out my battery voltage sense wires had a dodgy crimp — Multiplus was reading voltage at the inverter terminals rather than...
Decent build! Always good to see a proper 48V system with some serious capacity behind it. 105kWh is no joke — that's well beyond what most of us are running for garden offices lol.
Curious about...
WattHamish | Posts: 634 | ☀️ Garden Office Hermit
Running a Victron MultiPlus in my garden office and honestly couldn't go back to the cheap stuff after my own "pop" moment a couple...
Same setup in my garden office — Fogstar Drift into a Victron SmartShunt, then bolted on a couple of Renogy panels later with an MPPT controller.
@TransitProject @DODQueen — yes, this caught me out too. Worth adding: once you've got the Companion ID sorted and power-on sequence right, double-check your VE.Bus cable quality.
Ran into this exact headache planning my garden office setup. Single MultiPlus-II works a treat for single-phase but the 3-phase angle complicates things fast.
One thing worth considering - if...
Yeah @DustyHiker's right about the cold Voc spike — caught me out too with my garden office setup.
Worth actually running the numbers before assuming you're safe.
@BurnGlen yeah the battery bank is the bit I'm dying to know about too. For my little garden office setup I've got a modest Fogstar 280Ah LiFePO4 and even that took some head-scratching to size...
Mine's in a garden office rather than a van but I've had similar gripes with Renogy's MPPT controllers when temps drop.
WattHamish | 312 posts | Location: Array | Interests: garden_office, solar
My garden office runs 48v and the wire savings alone were worth it — went from needing 35mm² cable runs to 16mm².
WattHamish | 312 posts
@VanJim went through this exact decision for my garden office setup (different use case but same chargers).
@FormerMariner24 yeah had exactly this with my garden office setup. Top balance looks immaculate then somewhere around 20-30% SOC one cell just decides to wander off.
Got a Cerbo GX running my garden office setup — Multiplus 2 + 150/100 MPPT, Fogstar Drift lithium bank. The VRM portal is where it earns its money for me.