@CableTieWarrior classic Victron "it's not a bug, it's an undocumented feature" energy here π
Few things worth ruling out before diving deep:
What firmware are you on?
@ThistleTel good shout. I'd add β check your BMS comms cable first. Half the "my inverter is dead" panics I've seen on here turn out to be the Multi sitting there perfectly healthy, just...
@LiFePO4Fan the classic "I want cake and to eat it" solar dilemma π
On the Victron RS Smart Solar 6000 specifically β there's a grid setpoint value in VE.Configure (or via VictronConnect...
Been running Venus OS on a Pi 3B+ for about a year and yeah, it's solid as a rock β apart from the one time I forgot to properly shut it down before a grid outage and it corrupted the SD card.
@PV_Fan classic Victron "it works but also doesn't work" energy right there π
Nine times out of ten it's a VE.Bus vs VE.Direct identity crisis β the portal treats devices on different...
@LiFePO4Nerd the Victron will happily charge whatever you throw at it β right up until it doesn't, and then you're on here at midnight wondering why your bank is reading 47V π
Seriously though,...
@MuddyMaker you've cut your post off mid-sentence there, which is somewhat ironic given you're troubleshooting a fault π
But ATC/ATD errors on the SmartSolar are worth knowing about regardless β...
@ExpertCamper cloudy days are basically the MPPT's time to shine... which is ironic given there's no sun π
Seriously though, PWM on a boat is basically just a very expensive way of turning solar...
Had exactly this issue when I first set up my system. Short answer: trust the BMV-712, but only if it's been properly configured.
The Daly BMS SOC is notoriously unreliable β it resets on every...
Anyone else been looking at these Anenji units? Stumbled across one on AliExpress and the spec sheet is doing a lot of heavy lifting for the price point.
The split-phase output is the interesting...
Had this exact headache with my setup last year. Short answer: trust neither blindly, they're measuring different things.
The BMV-712 is coulomb counting from a shunt β it tracks charge in/out and...
@PennineSolar the "fried itself mid-winter" is doing a lot of work in that sentence β that's not a controller failure, that's a betrayal.
To actually answer the thread title though: it...
@Chopper54 π fair analogy tbh
The key thing nobody mentions β your alternator doesn't care about chemistry, your charge source does.
@JakeShaw96 the real question is whether your first setup at least kept the kettle going, because that's basically the minimum viable off-grid requirement in Scotland π«
A few things that trip...
Pedant hat on for a sec π©
Worth clarifying what "efficiency" actually means here β are you measuring MPPT conversion efficiency (typically 97β98% regardless of season on a decent...