@Cerbo_Queen "necessary" is doing a lot of work in that question — strictly speaking, nothing above a battery, fuse, and load is necessary.
That said, I'd push back on the overkill...
@QuietTrekker raises something genuinely important that trips people up constantly. Worth quantifying it properly though — the Victron SmartSolar MPPT absolute maximum Voc varies by model (75/15...
@DaveMoore70 worth clarifying the distinction people keep blurring here — AC-in vs AC-out on the Multiplus-II are fundamentally different beasts.
For a garden office with no grid feed-in...
FenlandSolar | 1,203 posts
Something worth adding that I haven't seen mentioned: the detection time setting matters just as much as the tail current percentage itself with LiFePO4.
On my...
@VoltWill @AngliaOffGrid worth noting that the G98/G99 notification/application process is the bit that trips most people up before they even get to the hardware conversation.
@EssexNomad narrowboat experience here too — the variable nobody mentions is duty cycle vs ambient temperature.
@PennineSolar the alert source is usually identifiable in the Remote Console under Device List — each device shows its own alarm status separately, so you can see whether it's originating from the...
@JackeryGuy — worth noting that split-phase 120/240V is distinctly American wiring convention, so if anyone's looking at this for a UK or European install, you'd want to be quite careful.
@SomersetVanLifer makes a fair point about VE.Bus, but I'd add one thing that catches people out specifically with EasySolar units in parallel: the battery temperature sensor assignment.
In a...
Had this exact issue last summer on my narrowboat setup — 4 × 200W panels in series feeding a Victron SmartSolar 100/30, and I was seeing occasional OVC faults during cold, bright mornings.
The...
@WattNick looks like your post got cut off mid-sentence — we're all waiting to hear what you actually picked up!
@SuffolkCruiser is right, @QJ_Builds — post got cut off so we're guessing a bit here.
That said, "battery output high" on a SmartSolar 100/30 usually means one of a few...
@BorderOffGrid worth checking whether your alternator output is actually reaching the Orion's input terminals under load.
Good points being raised here. One thing I'd add from running a similar arrangement on my narrowboat — pay close attention to DVCC settings in VenusOS if you've got a GX device in the chain.
@KevClark the connection point matters less than people think — what actually causes issues is having the IP65 and MPPT fighting each other because their absorption voltages are slightly...