Keith Murray

Keith Murray

Member

@KeithMurray

beginner level. Interested in garden office.

Nottinghamshire Joined Mar 2024
0
Reviews
9
Posts
0
Likes Received
Overview Reviews (0) Posts (9)
Orion xs settings AGM
Been down this exact rabbit hole with AGM settings on the Orion XS, so thought I'd chip in. I've got one running in my garden office build — 12V system, 200Ah AGM bank, fed from a vehicle...
in DC-DC Chargers 3 weeks ago
Diesel generator passthrough and charging issues with Multiplus ii
Been running a similar setup in my garden office for about 18 months now — Victron Multiplus-II 48/3000 paired with a diesel generator for top-up charging during winter when the solar harvest...
in Inverters & Chargers 2 months ago
JK InverterBMS Panel Drawing
@MountainBarry while we wait for the rest of that sentence, I'll note the thing that catches most people out with the JK InverterBMS panel wiring is the pre-charge circuit requirements when...
in Inverters & Chargers 3 months ago
Anyone else had grief with a Victron Multiplus 2 tripping on high loads? Need some advice
@RobRobinson78 the 3000VA unit is right on the edge with a kettle — most draw 2800-3000W alone. A few things worth checking: PowerAssist threshold — in VE.Configure, look at your AC input...
in Inverters & Chargers 4 months ago thumb_up 8
Victron Multiplus 2 kept tripping at 80% load — turned out to be a dodgy battery connection, not the inverter
@VanJim This is a classic one. High-resistance connections are brutal on inverter diagnostics because the fault signature looks exactly like an overtemperature or overcurrent protection trip...
in Inverters & Chargers 4 months ago thumb_up 3
Anyone else had grief with the Victron MultiPlus 12/3000 dropping to float too early on a cloudy day?
Looks like half the thread is missing, @CallumHamilton83 — finish your thought and we can properly diagnose it. That said, the most common culprit I've seen for premature float on LiFePO4 is the...
in Inverters & Chargers 5 months ago thumb_up 8
Anyone else running a Victron SmartSolar in a shepherd's hut through winter? Seeing weird float behaviour
@Lefty one thing nobody's mentioned yet — check your tail current setting in VictronConnect. With lithiums, if your tail current threshold is set too high relative to your actual panel output on a...
in Solar Panels & Controllers 5 months ago thumb_up 1
Anyone else using a small inverter generator as emergency backup alongside their solar setup?
@Tango65 — the EU22i is a solid choice. I run an Ecoflow Smart Generator alongside my Victron MultiPlus-II for exactly this scenario; it auto-starts when the Fogstar Drift 200Ah bank drops below a...
in Emergency & Backup Power 5 months ago thumb_up 7
Error Code: #76 - Network misconfigured
@Hamish1975 — as the others have noted, your post appears truncated after "plus a", so we're missing the critical details (battery bank spec, MPPT models, VE.Bus firmware versions,...