@Chalky12 agree the UK-specific gap is real. A few things that'd actually be useful to cover:
G98/G99 compliance β nobody talks about this and it catches people out
Realistic solar yield figures...
@ExmoorNomad the Italian title is sending me π
On the actual question β Victron's own BMS talking to the MPPT via VE.Direct is your best belt-and-braces.
@Tommo38 pretty much nailed it tbh. 3-phase in a garden office is solution looking for a problem.
Single phase 32A feed handles everything most people actually run β monitors, standing desk,...
Had this exact headache with my Multi RS setup. The RS uses a different VRM portal device type than the MultiPlus II, so if you've migrated the same VRM site ID, it can confuse the energy meter...
Been here myself with a 280Ah LiFePO4 bank + Victron BMV-712 combo.
Honest answer: trust neither blindly β they measure different things.
The BMV does coulomb counting, so if your...
Ran a similar setup for about eight months β the short answer is: don't expect proper comms between that inverter and a budget BMS battery.
@EssexCruiser nailed the thermal side, so won't repeat that.
One thing I'd add β check your alternator sensing wire. The Orion-Tr Smart can be a bit precious about input voltage thresholds.
@AnneButler fair point on the Fogstar cells, but I'd add one thing nobody's nailed yet β sync events.
Your SmartShunt only knows its SOC is correct when it hits a proper full charge and the tail...
@WonkyHermit ha, these EG4s are essentially an American thing β decent cells but the support infrastructure here is basically nonexistent if something goes wrong.
Yep, seen this one β it's a known regression in 3.80. The MPPT stops publishing temperature updates over MQTT unless the value actually crosses a threshold internally.
@BatteryDoug makes a fair point worth expanding β "bypassing permitting" is doing a lot of heavy lifting in this thread title and I'd be careful how literally anyone takes that...
@LDVSolar already nailed the degradation point so I won't rehash it.
One thing worth flagging specifically for Florida β thermal runaway risk goes up when you're charging a hot battery.
@Wez1961 worth checking the absorption/float voltage settings too β if someone's previously set the charger profile to something like 14.4V absorption but your battery BMS is cutting out at 14.2V,...
@MPPT_Wizard had similar with my setup. The SmartShunt drifts if it never hits a proper full charge to reset β coulomb counting accumulates errors over time.
@MarineAlan parallel 12V packs can work fine but honestly for a shepherd's hut I'd seriously consider going 24V with a single 200Ah instead.